10
Features and Main Functions
Section 1-1
Target Speed, Acceleration Rate, and Deceleration Rate Changes during
Acceleration or Deceleration
When a PULSE OUTPUT instruction with trapezoidal acceleration and decel-
eration is executed (for speed control or positioning), the target speed and
acceleration and deceleration rates can be changed during acceleration or
deceleration.
Lighting and Power Control by Outputting Variable Duty Ratio Pulses
Operations, such as lighting and power control, can be handled by outputting
variable duty ratio pulse (PWM) output signals from the CPU Unit's built-in
outputs.
Origin Searches (All
Models)
Origin Search and Origin Return Operations Using a Single Instruction
An accurate origin search combining all I/O signals (origin proximity input sig-
nal, origin input signal, positioning completed signal, error counter reset out-
put, etc.) can be executed with a single instruction. It is also possible to move
directly to an established origin using an origin return operation.
Input Interrupts (All
Models)
In direct mode, an interrupt task can be started when a built-in input turns ON
or OFF. In counter mode, the rising or falling edges of built-in inputs can be
counted, and an interrupt task started when the count reaches a specified
value. The maximum number of points is 8 for X and XA CPU Units and 6 for
Y CPU Units. (See note.)
Note
For each input point, a selection in the PLC Setup determines whether it is to
be used as a normal input, interrupt input, quick-response input, or high-
speed counter. The interrupt input response frequency in counter mode must
be 5 kHz or less total for all interrupts.
Quick-response
Inputs (All Models)
By using quick-response inputs, built-in inputs up to a minimum input signal
width of 30
µ
s can be read regardless of the cycle time.
The maximum number of points is 8 for X and XA CPU Units and 6 for Y CPU
Units. (See note.)
Note
For each input, a PLC Setup parameter determines whether it is to be used as
a normal input, interrupt input, quick-response input, or high-speed counter.
Analog I/O Function
(XA CPU Units Only)
XA CPU Units have analog I/O functionality, with 4 analog voltage/current
inputs and 2 analog voltage/current outputs built in.
• A wide range of applications is possible at a resolution of 6,000 or 12,000.
• Application is also possible for process-control sensor input or Inverter
control without using Expansion I/O Units.
0 to 5 V, 1 to 5 V,
0 to 10 V,
−
10 to 10 V
0 to 20 mA, 4 to 20 mA
0 to 5 V, 1 to 5 V,
0 to 10 V,
−
10 to 10 V
0 to 20 mA, 4 to 20 mA
4 analog inputs
2 analog outputs
Inverter, etc.
1
2
3
4
ON
Summary of Contents for CP1H CPU UNITS - PROGRAMMING 05-2007
Page 2: ......
Page 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Page 4: ...iv...
Page 10: ...x...
Page 18: ...xviii...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Page 370: ...336 Analog I O XA CPU Units Section 5 5...
Page 552: ...518 Trouble Shooting Section 8 7...
Page 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 598: ...564 Sample Application Section 9 12...
Page 642: ...608 Standard Models Appendix A...
Page 652: ...618 Dimensions Diagrams Appendix B...
Page 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Page 776: ...742 PLC Setup Appendix G...
Page 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Page 786: ...752 Revision History...