260
Pulse Outputs
Section 5-3
Operating Mode 1 with Origin Proximity Input Signal Reverse (Origin
Detection Method Setting = 0)
When the deceleration time is short, the Origin Input Signal can be detected
immediately after the Origin Proximity Input Signal goes from ON to OFF. Set
a Origin Proximity Input Signal dog setting that is long enough (longer than
the deceleration time.)
Operating Mode 1 without Origin Proximity Input Signal Reverse (Origin
Detection Method Setting = 1)
Depending on the length of the deceleration time, the stopping position may
change when the Origin Input Signal is detected during deceleration.
1
1
0
0
CCW
CCW
CW
CW
Origin Proximity
Input Signal
Origin Input Signal
(Phase-Z signal)
Pulse output
Verify that the Origin Proximity Input
Signal's dog setting is long enough
(longer than the deceleration time.)
Origin Input
Signal is
ignored during
deceleration.
Motor stopped by an Origin
Input Signal received after
deceleration.
Starts when
ORG(889) is
executed.
Stop
Ideal time for the Origin Proximity Input
Signal to go OFF.
(Settings when the
deceleration time is short)
Stop (See note.)
Starts when ORG(889)
is executed.
Note:
The Origin Input Signal can be detected immediately
after the Origin Proximity Input Signal goes from ON
to OFF if the deceleration time is short, e.g., starting
from within the Origin Proximity Input Signal.
1
1
0
0
CCW
CCW
CW
CW
Origin Proximity
Input Signal
Origin Input Signal
(Phase-Z signal)
(The deceleration time is
relatively long in this case.)
Pulse output
(The deceleration time is short
in this case.)
Origin Input
Signal is
ignored during
deceleration.
Motor stopped by an Origin
Input Signal received after
deceleration.
Starts when
ORG(889) is
executed.
Stop
Motor stopped by an
Origin Input Signal
received after
deceleration.
Starts when
ORG(889)
is executed.
Stop
Summary of Contents for CP1H CPU UNITS - PROGRAMMING 05-2007
Page 2: ......
Page 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Page 4: ...iv...
Page 10: ...x...
Page 18: ...xviii...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Page 370: ...336 Analog I O XA CPU Units Section 5 5...
Page 552: ...518 Trouble Shooting Section 8 7...
Page 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 598: ...564 Sample Application Section 9 12...
Page 642: ...608 Standard Models Appendix A...
Page 652: ...618 Dimensions Diagrams Appendix B...
Page 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Page 776: ...742 PLC Setup Appendix G...
Page 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Page 786: ...752 Revision History...