349
Serial Communications
Section 6-1
to the connected PT’s unit number and the addresses of Polled Units that are
not present in the network. These data areas are undefined in all nodes.)
Example: Complete Link Method, Highest Unit Number: 3
In the following diagram, Polled Unit No. 2 is either a PT or is a Unit not
present in the network, so the area allocated for Polled Unit No. 2 is undefined
in all nodes.
Example: Complete Link Method, Number of Link Words: 10
Each CPU Unit (either CP1H or CJ1M) sends data to the same words in all
other CPU Units for the Polling Unit and all Polled Units. The Polling Unit is a
CP1H CPU Unit in the following example, but it could also be a CJ1M CPU
Unit.
Polling Unit Link Method
The data for all the Polled Units in the Serial PLC Links ar reflected in the Poll-
ing Unit only, and each Polled Unit reflects the data of the Polling Unit only.
The advantage of the Polling Unit link method is that the addresses allocated
for the local Polled Unit data are the same in each Polled Unit, allowing data to
be accessed using common ladder programming. The areas allocated for the
unit numbers of the PT or Polled Units not present in the network are unde-
fined in the Polling Unit only.
Polling Unit
Polled Unit No.0
Polled Unit No.1
Polled Unit No.3
Local area
Polling Unit
Polling Unit
Polling Unit
Polled Unit
No.0
Local area
Polled Unit
No.0
Polled Unit
No.0
Polled Unit
No.1
Polled Unit
No.1
Local area
Polled Unit
No.1
Undefined
Undefined
Undefined
Undefined
Polled Unit
No.3
Polled Unit
No.3
Polled Unit
No.3
Local area
(Not used)
(Not used)
(Not used)
(Not used)
(Not used)
(Not used)
(Not used)
(Not used)
(Not used)
(Not used)
(Not used)
(Not used)
(Not used)
(Not used)
(Not used)
(Not used)
No.0
No.1
No.2
No.3
No.4
No.5
No.6
No.7
3100 to 3109
3110 to 3119
3120 to 3129
3130 to 3139
3140 to 3149
3150 to 3159
3160 to 3169
3170 to 3179
3180 to 3189
Serial PLC Link Words
(CIO Area)
No.0
No.1
No.2
No.3
No.4
No.5
No.6
No.7
3100 to 3109
3110 to 3119
3120 to 3129
3130 to 3139
3140 to 3149
3150 to 3159
3160 to 3169
3170 to 3179
3180 to 3189
No.0
No.1
No.2
No.3
No.4
No.5
No.6
No.7
3100 to 3109
3110 to 3119
3120 to 3129
3130 to 3139
3140 to 3149
3150 to 3159
3160 to 3169
3170 to 3179
3180 to 3189
No.0
No.1
No.2
No.3
No.4
No.5
No.6
No.7
3100 to 3109
3110 to 3119
3120 to 3129
3130 to 3139
3140 to 3149
3150 to 3159
3160 to 3169
3170 to 3179
3180 to 3189
CP1H CPU Unit
(Polling Unit)
Serial PLC Link Words
(CIO Area)
CP1H CPU Unit
(Polled Unit No. 0)
Serial PLC Link Words
(CIO Area)
CP1H CPU Unit
(Polled Unit No. 1)
Serial PLC Link Words
(CIO Area)
CJ1M CPU Unit
(Polled Unit No. 2)
Summary of Contents for CP1H CPU UNITS - PROGRAMMING 05-2007
Page 2: ......
Page 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Page 4: ...iv...
Page 10: ...x...
Page 18: ...xviii...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Page 370: ...336 Analog I O XA CPU Units Section 5 5...
Page 552: ...518 Trouble Shooting Section 8 7...
Page 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 598: ...564 Sample Application Section 9 12...
Page 642: ...608 Standard Models Appendix A...
Page 652: ...618 Dimensions Diagrams Appendix B...
Page 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Page 776: ...742 PLC Setup Appendix G...
Page 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Page 786: ...752 Revision History...