145
Overview of I/O Memory Area
Section 4-1
CPU Bus Unit Area
These words are used when connecting the CJ-series CPU Bus Units. Words
that aren’t used by CPU Bus Units may be used in programming.
Special I/O Unit Area
These words are used when connecting the CJ-series Special I/O Units.
Words that aren’t used by Special I/O Units may be used in programming.
Serial PLC Link Area
These words are allocated for use for data links (Serial PLC Links) with other
CP1H CPU Units or CJ1M CPU Units. Addresses not used for Serial PLC
Links can be used in programming.
DeviceNet Area
These words are allocated to slaves for remote I/O communications for CJ-
series DeviceNet Units. Allocations are fixed and cannot be changed. Words
that aren’t used by DeviceNet devices can be used in programming.
Note
The CPM1A-DRT21 CPM1A DeviceNet I/O Link Unit uses the I/O
area instead of the DeviceNet Area.
Internal I/O Area
These words can be used in programming; they cannot be used for I/O
exchange with external I/O terminals. Be sure to use the work words provided
in the Work Area before using words in the Internal I/O Area or other unused
words in the CIO Area. It is possible that these words will be assigned to new
functions in future versions of the CPU Units. The parts of the CIO Area that
are labelled “Not used” are functionally identical to the Internal I/O Area.
Work Area (W)
Words in the Work Area can be used in programming; they cannot be used for
I/O exchange with external I/O terminals. Use this area for work words and
bits before any words in the CIO Area.
Note
These words should be used first in programming be assigned to new func-
tions in future versions of CP1H CPU Units.
Holding Area (H)
Words in the Holding Area can be used in programming. These words retain
their content when the PLC is turned ON or the operating mode is switched
between PROGRAM mode and RUN or MONITOR mode.
15
W511
Word
Bit
15
H511
Word
Bit
Summary of Contents for CP1H CPU UNITS - PROGRAMMING 05-2007
Page 2: ......
Page 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Page 4: ...iv...
Page 10: ...x...
Page 18: ...xviii...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Page 370: ...336 Analog I O XA CPU Units Section 5 5...
Page 552: ...518 Trouble Shooting Section 8 7...
Page 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 598: ...564 Sample Application Section 9 12...
Page 642: ...608 Standard Models Appendix A...
Page 652: ...618 Dimensions Diagrams Appendix B...
Page 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Page 776: ...742 PLC Setup Appendix G...
Page 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Page 786: ...752 Revision History...