246
Pulse Outputs
Section 5-3
Switching from Continuous Mode (Speed Control) to Independent Mode (Positioning)
Relative Pulse Outputs and Absolute Pulse Outputs
Selecting Relative or
Absolute Coordinates
The pulse output PV's coordinate system (absolute or relative) is selected
automatically, as follows:
• When the origin is undetermined, the system operates in relative coordi-
nates.
• When the origin has been determined, the system operates in absolute
coordinates.
Example applica-
tion
Frequency changes
Description
Procedure
Instruction
Settings
Change from speed
control to fixed dis-
tance positioning
during operation
PLS2(887) can be
executed during a
speed control oper-
ation started with
ACC(888) to
change to position-
ing operation.
Note
An error will
occur if a
constant
speed can-
not be
achieved
after switch-
ing the mode.
If this hap-
pens, the
instruction
execution will
be ignored
and the previ-
ous opera-
tion will be
continued.
ACC(888)
(Continu-
ous)
↓
PLS2(887)
•Port
•Acceleration rate
•Deceleration rate
•Target frequency
•Number of pulses
Note
The starting fre-
quency is ignored.
Fixed distance feed
interrupt
Pulse frequency
Target
frequency
Outputs the number of
pulses specified in
PLS2(887) (Both relative
and absolute pulse
specification can be used.)
Execution of
ACC(888)
(continuous) Execution of
PLS2(887)
Time
Pulse
frequency
Present
frequency
Execution of
ACC(888)
(continuous) Execution of
PLS2(887) with the
following settings
•
Number of pulses = number
of pulses until stop
•
Relative pulse specification
•
Target frequency = present
frequency
•
Acceleration rate = Not 0
•
Deceleration rate = target
deceleration rate
Time
Conditions
Origin has been
determined by an ori-
gin search
Origin has been
determined by exe-
cuting INI(880) to
change the PV
Origin not estab-
lished (Origin search
has not been per-
formed and PV has
not been changed
with INI(880).)
Pulse output
PV's coordi-
nate system
Absolute coordinates
Relative coordinates
Summary of Contents for CP1H CPU UNITS - PROGRAMMING 05-2007
Page 2: ......
Page 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Page 4: ...iv...
Page 10: ...x...
Page 18: ...xviii...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Page 370: ...336 Analog I O XA CPU Units Section 5 5...
Page 552: ...518 Trouble Shooting Section 8 7...
Page 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 598: ...564 Sample Application Section 9 12...
Page 642: ...608 Standard Models Appendix A...
Page 652: ...618 Dimensions Diagrams Appendix B...
Page 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Page 776: ...742 PLC Setup Appendix G...
Page 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Page 786: ...752 Revision History...