259
Pulse Outputs
Section 5-3
When the Origin Input Signal is received, the pulse output will be stopped and
the Error Counter Reset Signal will be output for about 20 to 30 ms.
When the Origin Proximity Input Signal is received, the motor will begin decel-
erating from the origin search high speed to the origin search proximity speed.
In this operating mode, the motor will stop at the Origin Input Signal after
deceleration is completed.
1
1
0
0
Approx. 20 to 30 ms
Origin Input Signal
(Phase-Z signal)
Pulse output
Error Counter Reset
Signal