background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.promax.it

 

Summary of Contents for NGM EVO

Page 1: ...www promax it ...

Page 2: ... liability for errori or inaccuracies that may be found in this manual Except as permitted by the license no part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without prior permission Promax srl Any references to company names and products are for demonstration purposes only and does not a...

Page 3: ...0 V 16 Digital Inputs PNP 24 Vdc 14 Digital Outputs PNP 24 VDC up to 0 5 A with internal protection 4 Channels STEP DIR 400 Khz Position Mode 125 Khz Interpolation Mode Line Drive or Open Collector 1 Input encoder Line Drive NGMIO EXPANSION Max 4 Expansions 1 16 Digital Inputs PNP 24 Vdc 14 Digital Outputs PNP 24 VDC up to 1 A NGMsX EXPANSION Max 3 Expansions 1 2 Channels STEP DIR 500 Khz Position...

Page 4: ... C Analog Inputs 4 20 Ma 0 Without Analog Outputs 1 1 Analog Output 0 10 V on Digital Out 1 0 16 Kb FRAM Permanent Memory 1 32 Kb FRAM Permanent Memory xxxxxxxx Number configured channels analog inputs ex B123 Channels 1 2 3 configured 0 10 Volt ORDER CODE NGMIO NGMIO ORDER CODE NGMsX NGMsX 1 1 Channel STEP DIR Line Drive 500 Khz 2 2 Channels STEP DIR Line Drive 500 Khz 0 Without Encoder Channel 2...

Page 5: ...5 NGM EVO USER GUIDE 3 NGM EVO Connections UP DOWN FRONT ...

Page 6: ...igital outputs see the relevant chapter 4 9 As regards the supply of the logic section this is necessary for normal operation of the card 4 1 1 Electrical Characteristics U m Min Standard Max DC IN Vdc 12 24 35 Power to 24Vdc W 2 6 THE SYSTEM IS PROTECTED FROM POLARITY INVERSION WARNING DO NOT EXCEEDS THE MAXIMUM VOLTAGE VALUE ADMITTED BECAUSE THE CARD CAN BE DAMAGED ...

Page 7: ...re SER2 Can be used for communication with other devices such as a PLC inverters or other CAN BE CONFIGURED RS485 MODE For the electrical signal the serial ports are in compliance with RS232 RS485 Use a CABLE WITH SHIELD for serial ports connections Connect the SHIELD to PIN 5 SER1 or SER2 to NGMEVO ports Generally the RS232 connection uses a NULL MODEM cable pin 2 3 5 CROSSOVER with inversion on ...

Page 8: ...8 NGM EVO USER GUIDE 4 2 1 Connections J6 SER1 PROG J11 SER2 WARNING DO NOT EXCEEDS THE MAXIMUM VOLTAGE VALUE ADMITTED BECAUSE THE CARD CAN BE DAMAGED ...

Page 9: ... the firmware present The port CAN BUS meets the specifications of ISO 11898 24V 4 3 1 Connection CAN BUS Is possible insert the TERMINATOR RESISTOR inserting the JUMPER above the power connector WARNING If the NGMEVO board is configured as MASTER insert always the TERMINATOR JUMPER If the NGMEVO is configured as SLAVE insert the TERMINATOR JUMPER if the board is the last node in the CanBus In ano...

Page 10: ... 4 Ohm Km 21AWG 43 6 Ohm Km PAIR CAPACITY 50 pF m IMPEDENCE 120 Ohm TRASMISSION SPEED CABLE LENGTH Baud rate 1Mb Length Max 25 Mt Baud rate 800 Kb Length Max 50 Mt Baud rate 500 Kb Length Max 100 Mt Baud rate 250 Kb Length Max 250 Mt Baud rate 125Kb Length Max 500 Mt VOLTAGE EXERCISE 30 V ...

Page 11: ...a PROMAX specific protocol PLC and other devices communication with ModBus TCP IP protocol 4 4 1 Connections The on board connector complies the RJ45 standard It s recommended to use PC with Ethernet ports complies this standard It s recommended to use cables length conformed the standard The connection cable can be CROSSOVER or NORMAL The port is automatically adapted to cable type WARNING USE TH...

Page 12: ...tage can exceed the full scale is not more than 0 2 V The use of analog input remove automatically a digital input see the following table Reference table for exclusion digital inputs Analog Input Configured Digital Input Removed 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 16 4 5 1 Analog Inputs Connections J12 4 5 2 Input Resistance MIN TIPICA MAX VDC 25 Kῼ 72 Kῼ 4 20 Ma 175 ῼ 4 5 3 External resistance f...

Page 13: ... board can be configure one analog output 0 10V 4 6 1 Electric characteristics U m Min Max Analog Output Voltage Vdc 0 10 10 Kῼ WARNING DO NOT EXCEEDS 0 2 Volt THE MAXIMUM VALUE SELECTED THE ANALOG INPUT CAN BE DAMAGED THE BOARD WARNING THIS CONFIGURATION ELIMINATES THE DIGITAL OUTPUT 1 ...

Page 14: ...ignals or LINE DRIVE 4 7 1 OPEN COLLECTOR POWER MAX 48 VDC LOAD 100 Ma continuativo 500 Ma picco STATE ON voltage MIN 0V MAX 1V FREQUENCY MAX 30 Khz 4 7 2 LINE DRIVE OUTPUT DIFFERENTIAL MIN 2 2V MAX 3 3V specific TIA EIA 422 B RS422 FREQUENCY MAX 400 Khz in position mode 125 Khz in interpolation mode specifics TIA EIA 422 B RS422 LOAD V Min V Typical 3 9 Kῼ 3 2 V 100 ῼ 2 2 6 V WARNING USE A CABLE ...

Page 15: ...15 NGM EVO USER GUIDE 4 7 3 Connections OPEN COLLECTOR J13 J14 J13 J13 J14 ...

Page 16: ...16 NGM EVO USER GUIDE 4 7 4 Connections LINE DRIVE J13 J14 ...

Page 17: ...ally used for HANDWHEEL FUNCTION It means that the frequency inputs is not to high 4 8 1 Electric characteristics U m Min Soglia Max On voltage level Vdc 0 0 8 Off volatge level Vdc 4 12 R input Ω 6 Frequency KHz 32 T0 PNP Index On level Vdc 2 5 2 2 7 7 Off level Vdc 0 1 5 T0 NPN Index On level Vdc 0 1 4 1 Off level Vdc 2 7 7 If is used the PULSE DIR channels the frequency can be decreased ...

Page 18: ...18 NGM EVO USER GUIDE 4 8 2 Example WARNING USE A CABLE WITH SHIELD FOR THE CONNECTIONS WARNING The Power for encoder MUST BE EXTERNAL ...

Page 19: ...t bring a positive VDC 24 Vdc typical on the desired channel refers to the common inputs 4 9 1 Electric characteristics U m Min Standard Max State On Vdc 10 24 28 State Off Vdc 0 4 Delay ON ms 3 24Vdc OFF ms 2 24Vdc Current mA 4 10Vdc 14 28Vdc 4 9 2 Connections J1 J2 WARNING DO NOT EXCEEDS THE VOLTAGE LEVEL ABOVE DESCRIBED ...

Page 20: ...a protection diode so you can also directly drive inductive loads In case of inductive loads with absorption greater than or equal to 0 5 A or when the cable connection between the load and board exceeds a length of 3 meters you should put the protection diode also close to the load diode type 1N4007 or similar 4 10 1 Electric characteristics U m Min Standard Max Note Power Vdc 12 24 30 Load A 0 5...

Page 21: ... 3 NGPROG The application was developed by Promax NGPROG to allow the update software and firmware of the new controls based on μP ColdFire 5 3 1 Upload firmware 1 Press button FIRMWARE MANAGEMENT on NGProg 2 If you use UPDATE da File use the standard windows Browser for find the SREC file 2 If you use UPDATE da Server you must have a intenet active connection NGPROG search in Promax server the ne...

Page 22: ...nsion for NGMEVO local BUS 16 Digital Inputs 14 Digital Outputs Can Be insert up to 4 expansions NGMIO for a total 80 Digital Inputs 70 Digital Outputs The digital I O are the same specifics to NGMEVO I O see Chapr 4 8 and 4 9 102 mm 21 50 mm Up Down Front UP DOWN FRONT ...

Page 23: ...23 NGM EVO USER GUIDE 7 1 Connections NGMIO J1 J2 7 2 Connections NGMIO J3 J4 REFER TO CHAPTERS 4 8 AND 4 9 FOR CONNECTIONS AND WARNINGS ...

Page 24: ...nnels encoder Line Drive 500 Khz 2 Analog Outputs 10 V 12 bit Can Be insert up to 3 expansions NGMsX Can be managed the following combinations for a NGMsX expansion 2 Channels STEP DIR 2 Channels STEP DIR and 2 Analog Outputs 1 Channel STEP DIR 2 Analog Outputse 2 Channels Encoder 1 Channel STEP DIR and 2 Channels Encoder 102 mm 21 50 mm Front Up Down UP DOWN FRONT ...

Page 25: ...P DIR on NGMsX Expansion The NGMsX board can use 2 channels STEP DIR up to 500 Khz clock for single channel The outputs are type LINE DRIVE 5V OUPUT MIN 3V MAX 5V CLOCK MAX 500 Khz J21 J21 WARNING USE A CABLE WITH SHIELD FOR THE CONNECTIONS ...

Page 26: ...o use LINE DRIVE encoders also supplies the 5Vdc source voltage It can t be used with PUSH PULL or OPEN COLLECTOR encoders In case of motor drives encoder simulation is not necessary to connect the Vdc supply but only the GND 8 2 1 Electric characteristics U m Min Soglia Max On voltage level Vdc 0 0 8 Off volatge level Vdc 4 12 R input Ω 6 Frequency KHz 500 T0 PNP Index On level Vdc 2 5 2 2 7 7 Of...

Page 27: ...27 NGM EVO USER GUIDE 8 2 3 Example J22 J23 WARNING USE A CABLE WITH SHIELD FOR THE CONNECTIONS ...

Page 28: ...d can use TWO analog outputs 10 V 12 bit and TWO RELE CONTACTS 8 3 1 Electric characteristics U m Min Standard Max Analog Output Output voltage Vdc 10 9 995 Output impedence Ω 250 290 Relè Conctat Voltage Vdc 35 Current A 1 WARNING USE A CABLE WITH SHIELD FOR THE CONNECTIONS ...

Page 29: ...29 NGM EVO USER GUIDE 9 Dimensions N expansions number NGMIO or NGMsx ...

Page 30: ...egislation about On electromagnetic compatibility regarding the 2004 108 CE norm this device can be classified as a finished appliance Due to the fact that the NGMEVO will be normally integrated inside a complex electromechanics system the machine electric board by a manufacturer in an industrial ambit and not by a final customer it haven t any certification duty PROMAX however can institute some ...

Page 31: ...thernet Port 11 4 4 1 Connections 11 4 5 Analog inputs 12 4 5 1 Analog Inputs Connections J12 12 4 5 2 Input Resistance 12 4 5 3 External resistance for voltages other than 0 10V or 4 20Ma 12 4 5 4 Connection example 13 4 6 Analog Output on NGMEVO 13 4 6 1 Electric characteristics 13 4 7 Channels STEP DIR 14 4 7 1 OPEN COLLECTOR 14 4 7 2 LINE DRIVE 14 4 7 3 Connections OPEN COLLECTOR J13 J14 15 4 ...

Page 32: ... Status Led 21 7 NGMIO Connections 22 7 1 Connections NGMIO J1 J2 23 7 2 Connections NGMIO J3 J4 23 8 NGMsX Connections 24 8 1 Channels STEP DIR on NGMsX Expansion 25 8 2 Channels ENCODER on NGMsX Expansion 26 8 2 1 Electric characteristics 26 8 2 2 Electric characteristics 5vdc output encoder supply 26 8 2 3 Example 27 27 8 3 Analog Outputs on NGMsX Expansion 28 8 3 1 Electric characteristics 28 ...

Reviews: