667
Auxiliary Area Allocations by Address
Appendix D
A439
All
Pulse Output
3 Stop Error
Code
If a Pulse Output Stop Error occurs
for pulse output 3, the error code is
stored.
---
Retained
Cleared
Refreshed
when ori-
gin search
starts.
Refreshed
when a
pulse out-
put stop
error
occurs.
---
A440
All
Max. Interrupt
Task Process-
ing Time
Contains the Maximum Interrupt
Task Processing Time in units of
0.1 ms.
(This value is written after the inter-
rupt task with the max. processing
time is executed and cleared when
PLC operation begins.)
0000 to FFFF
hexadecimal
Cleared
Cleared
See Func-
tion col-
umn.
---
A441
All
Interrupt Task
With Max.
Processing
Time
Contains the task number of the
interrupt task with the maximum pro-
cessing time. Hexadecimal values
8000 to 80FF correspond to task
numbers 00 to FF. Bit 15 is turned
ON when an interrupt has occurred.
(This value is written after the inter-
rupt task with the max. processing
time is executed and cleared when
PLC operation begins.)
8000 to 80FF
hexadecimal
Cleared
Cleared
See Func-
tion col-
umn.
---
A444
All
Pulse Output
0 Stop Error
Code
If a Pulse Output Stop Error occurs
for pulse output 0, the error code is
written to this word.
---
---
Cleared
Refreshed
when ori-
gin search
starts.
Refreshed
when a
pulse out-
put stop
error
occurs.
---
A445
Pulse Output
1 Stop Error
Code
If a Pulse Output Stop Error occurs
for pulse output 1, the error code is
written to this word.
---
---
---
A494
A494.00
to
A494.07
Memory
Casette Verifi-
cation Results
Stores the results of comparing data
in the Memory Cassette and CPU
Unit. This information is cleared the
next time the Memory Cassette is
accessed normally (initialized, writ-
ten, read, or compared).
A494.00: User program is different.
A494.01: Function block sources are
different.
A494.02: Parameter area is different.
A494.03: Symbol table is different.
A494.04: Comments are different.
A494.05: Program indices are differ-
ent.
A494.06: Data memory is different.
A494.07: DM initial values are differ-
ent.
OFF: Match
ON: Mis-
match
When
Memory
Cassette is
compared.
Address
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words
Bits
Summary of Contents for CP1H CPU UNITS - PROGRAMMING 05-2007
Page 2: ......
Page 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Page 4: ...iv...
Page 10: ...x...
Page 18: ...xviii...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Page 370: ...336 Analog I O XA CPU Units Section 5 5...
Page 552: ...518 Trouble Shooting Section 8 7...
Page 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 598: ...564 Sample Application Section 9 12...
Page 642: ...608 Standard Models Appendix A...
Page 652: ...618 Dimensions Diagrams Appendix B...
Page 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Page 776: ...742 PLC Setup Appendix G...
Page 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Page 786: ...752 Revision History...