625
Auxiliary Area Allocations by Function
Appendix C
Task Information
Debugging Information
Online Editing
Output Control
Differentiate Monitor
Data Tracing
Name
Address
Description
Access
Updated
Task Number when Program
Stopped
A294
This word contains the task number of the task that was
being executed when program execution was stopped
because of a program error.
Read-only
Maximum Interrupt Task
Processing Time
A440
Contains the Maximum Interrupt Task Processing Time
in units of 0.1 ms as hexadecimal data.
Read-only
Interrupt Task with Max.
Processing Time
A441
Contains the task number of the interrupt task with the
maximum processing time. Hexadecimal values 8000 to
80FF correspond to task numbers 00 to FF. Bit 15 is
turned ON when an interrupt has occurred.
Read-only
IR/DR Operation between
Tasks
A99.14
ON when index and data registers are shared between
all tasks.
OFF: Independent
ON: Shared (default)
Read-only
Name
Address
Description
Access
Updated
Online Editing Wait Flag
A201.10
ON when an online editing process is waiting.
Read-only
Online Editing Processing
Flag
A201.11
ON when an online editing process is being executed.
Read-only
Online Editing Disable Bit
Validator
A527.00 to
A527.07
The Online Editing Disable Bit (A527.09) is valid only
when this byte contains 5A.
Read/write
Online Editing Disable Bit
A527.09
Turn this bit ON to disable online editing. The setting of
this bit is valid only when A527.00 to A527.07 have been
set to 5A.
Read/write
Name
Address
Description
Access
Updated
Output OFF Bit
A500.15
Turn this bit ON to turn OFF all outputs from the CPU
Unit, CP-series Units, and Special I/O Units.
Read/write
Name
Address
Description
Access
Updated
Differentiate Monitor Com-
pleted Flag
A508.09
ON when the differentiate monitor condition has been
established during execution of differentiation monitoring.
Read/write
Name
Address
Description
Access
Updated
Sampling Start Bit
A508.15
When a data trace is started by turning this bit ON from
the CX-Programmer, the PLC will begin storing data in
Trace Memory by one of the three following methods:
Data is sampled at regular intervals (10 to 2,550 ms).
Data is sampled when TRSM(045) is executed in the
program.
Data is sampled at the end of every cycle.
Read/write
Trace Start Bit
A508.14
Turn this bit ON to establish the trigger condition. The off-
set indicated by the delay value (positive or negative)
determines which data samples are valid.
Read/write
Trace Busy Flag
A508.13
ON when the Sampling Start Bit (A508.15) is turned ON.
OFF when the trace is completed.
Read/write
Trace Completed Flag
A508.12
ON when sampling of a region of trace memory has
been completed during execution of a trace.
Read/write
Trace Trigger Monitor Flag
A508.11
ON when a trigger condition is established by the Trace
Start Bit (A508.14). OFF when the next data trace is
started by the Sampling Start Bit (A508.15).
Read/write
Summary of Contents for CP1H CPU UNITS - PROGRAMMING 05-2007
Page 2: ......
Page 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Page 4: ...iv...
Page 10: ...x...
Page 18: ...xviii...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Page 370: ...336 Analog I O XA CPU Units Section 5 5...
Page 552: ...518 Trouble Shooting Section 8 7...
Page 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 598: ...564 Sample Application Section 9 12...
Page 642: ...608 Standard Models Appendix A...
Page 652: ...618 Dimensions Diagrams Appendix B...
Page 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Page 776: ...742 PLC Setup Appendix G...
Page 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Page 786: ...752 Revision History...