521
Ethernet Option Board Function Guide
Section 9-1
9-1-2
Connecting the CX-Programmer to PLCs Online via Ethernet
Connecting within the
Same Segment
Use the UDP/IP version of the FINS communications service (i.e.,
FINS/UDP). FINS/UDP is supported by many OMRON products and is com-
patible with earlier Ethernet Units (CS1W-ETN01/ETN11/ETN21 and CJ1W-
ETN11/ETN21). The CX-Programmer can be connected and used with
FINS/UDP.
Connecting through
Multiple Segments
Use the TCP/IP version of the FINS communications service (i.e., FINS/TCP).
It provides automatic recovery at the TCP/IP layer from communications
errors (such as packet loss) that occur during multilevel routing. For CX-Pro-
grammer, FINS/TCP can be used to directly connect to the PLC online.
Using Media with
Unreliable Connections,
Such as a Wireless LAN
Use the TCP/IP version of the FINS communications service (i.e., FINS/TCP).
It provides automatic recovery at the TCP/IP layer from communications
errors (such as packet loss) resulting from unreliable connections. For CX-
Programmer, FINS/TCP can be used to directly connect to the PLC online.
Connecting from a
Personal Computer with a
Dynamic Private IP
Address
Depending on whether or not the connection will be within the same segment,
either use an IP address conversion method for dynamic IP addresses in the
UDP/IP version of the FINS communications service or use the TCP/IP ver-
sion of the FINS communications service.
It is possible to connect online to a PLC using the CX-Programmer from a
computer serving as a temporarily connected node or a permanent DHCP cli-
ent.
For CX-Programmer, FINS/TCP can be used to directly connect to the PLC
online.
Connecting through multiple segments, such as over the Internet:
Use FINS/TCP.
FINS
Internet
IP router
Firewall
Intranet
(Office floor)
CX-Programmer
FINS
Ethernet
Ethernet
Router
(Production line)
Ethernet
Connecting within the same segment:
Use FINS/UDP.
PLC
PLC
Wireless
FINS
Using media with unreliable
connections, such as wireless
LAN: Use FINS/TCP.
FINS
Connecting from a computer with a dynamic private IP address:
Use FINS/TCP or FINS/UDP.
CX-Programmer
CX-Programmer
Ethernet Option Board
Ethernet Option Board
CX-Programmer
Router
Summary of Contents for CP1H CPU UNITS - PROGRAMMING 05-2007
Page 2: ......
Page 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Page 4: ...iv...
Page 10: ...x...
Page 18: ...xviii...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Page 370: ...336 Analog I O XA CPU Units Section 5 5...
Page 552: ...518 Trouble Shooting Section 8 7...
Page 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 598: ...564 Sample Application Section 9 12...
Page 642: ...608 Standard Models Appendix A...
Page 652: ...618 Dimensions Diagrams Appendix B...
Page 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Page 776: ...742 PLC Setup Appendix G...
Page 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Page 786: ...752 Revision History...