654
Auxiliary Area Allocations by Address
Appendix D
A322
and
A323
All
Pulse Output
2 PV
Contain the number of pulses output
from the corresponding pulse output
port.
PV range: 80000000 to 7FFFFFFF
hex
(-2,147,483,648 to 2,147,483,647)
When pulses are being output in the
CW direction, the PV is incremented
by 1 for each pulse.
When pulses are being output in the
CCW direction, the PV is decre-
mented by 1 for each pulse.
PV after overflow: 7FFFFFFF hex
PV after underflow: 80000000 hex
A323 contains the leftmost 4 digits
and A322 contains the rightmost 4
digits of the pulse output 2 PV.
A325 contains the leftmost 4 digits
and A324 contains the rightmost 4
digits of the pulse output 3 PV.
Cleared when operation starts.
Note
If the coordinate system is
relative coordinates (unde-
fined origin), the PV will be
cleared to 0 when a pulse
output starts, i.e. when a
pulse output instruction
(SPED(885), ACC(888), or
PLS2(887)) is executed.
---
---
Cleared
Refreshed
each cycle
during
oversee
process.
Refreshed
when the
INI(880)
instruction
is exe-
cuted (PV
change).
---
A324
and
A325
All
Pulse Output
3 PV
Cleared
---
A326
A326.00 Pulse Output
2 Accel/Decel
Flag
This flag will be ON when pulses are
being output from pulse output 2
according to an ACC(888) or
PLS2(887) instruction and the output
frequency is being changed in steps
(accelerating or decelerating).
Cleared when operation starts or
stops.
OFF: Constant speed
ON: Accelerating or decelerating
---
---
Cleared
Refreshed
each cycle
during
oversee
process.
---
A326.01 Pulse Output
2
Overflow/
Underflow
Flag
This flag indicates when an overflow
or underflow has occurred in the
pulse output 2 PV.
Cleared when operation starts.
OFF: Normal
ON: Overflow or underflow
---
---
Cleared
Cleared
when the
PV is
changed
by the
INI(880)
instruction.
Refreshed
when an
overflow or
underflow
occurs.
---
A326.02 Pulse Output
2 Output
Amount Set
Flag
ON when the number of output
pulses for pulse output 2 has been
set with the PULS(886) instruction.
Cleared when operation starts or
stops.
OFF: No setting
ON: Setting made
---
---
Cleared
Refreshed
when the
PULS(886)
instruction
is exe-
cuted.
Refreshed
when pulse
output
stops.
---
A326.03 Pulse Output
2 Output
Completed
Flag
ON when the number of output
pulses set with the PULS(886) or
PLS2(887) instruction has been out-
put through pulse output 2.
Cleared when operation starts or
stops.
OFF: Output not completed.
ON: Output completed.
---
---
Cleared
Refreshed
at the start
or comple-
tion of
pulse out-
put in inde-
pendent
mode.
---
Address
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words
Bits
Summary of Contents for CP1H CPU UNITS - PROGRAMMING 05-2007
Page 2: ......
Page 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised March 2009...
Page 4: ...iv...
Page 10: ...x...
Page 18: ...xviii...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 174: ...140 CP series Expansion I O Unit Wiring Section 3 6...
Page 370: ...336 Analog I O XA CPU Units Section 5 5...
Page 552: ...518 Trouble Shooting Section 8 7...
Page 595: ...561 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 598: ...564 Sample Application Section 9 12...
Page 642: ...608 Standard Models Appendix A...
Page 652: ...618 Dimensions Diagrams Appendix B...
Page 745: ...711 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 746: ...712 Connections to Serial Communications Option Boards Appendix F...
Page 776: ...742 PLC Setup Appendix G...
Page 778: ...744 Specifications for External Power Supply Expansion Appendix H...
Page 786: ...752 Revision History...