8-Port Gigabit (PoE+) Ethernet Smart Managed Pro Switch with (2 SFP or 2 Copper Ports and)
Cloud
Management
Configure Switching
User Manual
174
7.
Select whether to display physical interfaces, LAGs, or both by clicking one of the following
links above the table heading:
•
1
(the unit ID of the switch). Only physical interfaces are displayed. This is the default
setting.
•
LAG
. Only LAGs are displayed.
•
All
. Both physical interfaces and LAGs are displayed.
8.
Select one or more interfaces by taking one of the following actions:
•
To configure a single interface, select the check box associated with the port, or type
the port number in the
Go To Interface
field and click the
Go
button.
•
To configure multiple interfaces with the same settings, select the check box
associated with each interface.
•
To configure all interfaces with the same settings, select the check box in the heading
row.
9.
From the
Auto VoIP Mode
menu, select
Disable
or
Enable
.
Auto-VoIP is disabled by default.
10.
Click the
Apply
button.
Your settings are saved.
The Operational Status field displays the current operational status of an interface.
Manage the OUI table
Device hardware manufacturers can include an OUI in a network adapter to help identify a
hardware device. The OUI is a unique 24-bit number assigned by the IEEE registration
authority. The switch comes preconfigured with the following OUIs that identify the IP phone
manufacturer:
•
00:01:E3: SIEMENS
•
00:03:6B: CISCO1
•
00:12:43: CISCO2
•
00:60:B9: NITSUKO
•
00:D0:1E: PINTEL
•
00:E0:75: VERILINK
•
00:E0:BB: 3COM
•
00:04:0D: AVAYA1
•
00:1B:4F: AVAYA2
You can select an existing OUI or add a new OUI and description to identify the IP phones on
the network.