Configuring a Maintenance Association End Point
To configure a maintenance association end point:
1.
Specify an ID for the MEP. The value can be from 1 through 8191.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain
domain-name
maintenance-association
ma-name
]
user@switch#
set
mep
mep-id
]
2.
Enable maintenance endpoint automatic discovery if you want to have the MEP accept
continuity check messages (CCMs) from all remote MEPs of the same maintenance
association:
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain
domain-name
maintenance-association
ma-name
mep
mep-id
user@switch#
set
auto-discovery
3.
You can specify that CFM packets (CCMs) be transmitted only in one direction for the
MEP, that is, the direction be set as
down
so that CCMs are transmitted only out of
(not into) the interface configured on this MEP.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain
domain-name
maintenance-association
ma-name
mep
mep-id
]
user@switch#
set
direction
down
4.
Specify the logical interface to which the MEP is attached. It can be either an access
interface or a trunk interface. If you specify a trunk interface, the VLAN associated
with that interface must have a VLAN ID.
NOTE:
You cannot associate an access interface that belongs to multiple
VLANs with the MEP.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain
domain-name
maintenance-association
ma-name
mep
mep-id
]
user@switch#
set interface interface-name
5.
You can configure a remote MEP from which CCMs are expected. If autodiscovery is
not enabled, the remote MEP must be configured under the
mep
statement. If the
remote MEP is not configured under the
mep
statement, the CCMs from the remote
MEP are treated as errors.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain
domain-name
maintenance-association
ma-name
mep
mep-id
]
user@switch#
set
remote-mep
mep-id
Configuring a Connectivity Fault Management Action Profile
You can configure an action profile and specify the action to be taken when any of the
configured events occur. Alternatively, you can configure an action profile and specify
default actions when connectivity to a remote MEP fails.
To configure an action profile:
1.
Specify a name for an action profile:
3771
Copyright © 2010, Juniper Networks, Inc.
Chapter 132: Ethernet OAM Connectivity Fault Management
Summary of Contents for JUNOS OS 10.3 - SOFTWARE
Page 325: ...CHAPTER 17 Operational Mode Commands for System Setup 229 Copyright 2010 Juniper Networks Inc ...
Page 1323: ...CHAPTER 56 Operational Mode Commands for Interfaces 1227 Copyright 2010 Juniper Networks Inc ...
Page 2841: ...CHAPTER 86 Operational Commands for 802 1X 2745 Copyright 2010 Juniper Networks Inc ...
Page 3367: ...CHAPTER 113 Operational Mode Commands for CoS 3271 Copyright 2010 Juniper Networks Inc ...
Page 3435: ...CHAPTER 120 Operational Mode Commands for PoE 3339 Copyright 2010 Juniper Networks Inc ...
Page 3529: ...CHAPTER 126 Operational Mode Commands for MPLS 3433 Copyright 2010 Juniper Networks Inc ...