![Juniper JUNOS OS 10.3 - SOFTWARE Manual Download Page 3774](http://html.mh-extra.com/html/juniper/junos-os-10-3-software/junos-os-10-3-software_manual_20327933774.webp)
Table 488: show snmp health-monitor Output Fields
(continued)
Level of Output
Field Description
Field Name
All levels
State of the alarm or event entry:
•
Alarms:
•
active
—Entry is fully configured and activated.
•
falling threshold crossed
—Value of the variable has crossed the lower
threshold limit.
•
rising threshold crossed
—Value of the variable has crossed the upper
threshold limit.
•
under creation
—Entry is being configured and is not yet activated.
•
startup
—Alarm is waiting for the first sample of the monitored variable.
•
object not available
—Monitored variable of that type is not available to
the health monitor agent.
•
instance not available
—Monitored variable's instance is not available to
the health monitor agent.
•
object type invalid
—Monitored variable is not a numeric value.
•
object processing errored
—An error occurred when the monitored variable
was processed.
•
unknown
—State is not one of the above.
State
detail
Object ID to which the variable name is resolved. The format is
x.x.x.x
.
Variable OID
detail
Method of sampling the monitored variable and calculating the value to compare
against the upper and lower thresholds. It can have the value of
absolute value
or
delta value
.
Sample type
detail
Alarm that might be sent when this entry is first activated, depending on the
following criteria:
•
Alarm is sent when one of the following situations exists:
•
Value of the alarm is above or equal to the rising threshold and the startup
type is either
rising alarm
or
rising or falling alarm.
•
Value of the alarm is below or equal to the falling threshold and the startup
type is either
falling alarm
or
rising or falling alarm
.
•
Alarm is
not
sent when one of the following situations exists:
•
Value of the alarm is above or equal to the rising threshold and the startup
type is
falling alarm
.
•
Value of the alarm is below or equal to the falling threshold and the startup
type is
rising alarm
.
•
Value of the alarm is between the thresholds.
Startup alarm
detail
Name of the entry configured by the user. If the entry was created through the
CLI, the owner has
monitor
prepended to it.
Owner
detail
Mechanism by which the entry was configured (
Health Monitor
).
Creator
detail
Time period between samples (in seconds).
Sample interval
detail
Upper limit threshold value as a percentage of the maximum possible value.
Rising threshold
Copyright © 2010, Juniper Networks, Inc.
3678
Complete Software Guide for Junos
®
OS for EX Series Ethernet Switches, Release 10.3
Summary of Contents for JUNOS OS 10.3 - SOFTWARE
Page 325: ...CHAPTER 17 Operational Mode Commands for System Setup 229 Copyright 2010 Juniper Networks Inc ...
Page 1323: ...CHAPTER 56 Operational Mode Commands for Interfaces 1227 Copyright 2010 Juniper Networks Inc ...
Page 2841: ...CHAPTER 86 Operational Commands for 802 1X 2745 Copyright 2010 Juniper Networks Inc ...
Page 3367: ...CHAPTER 113 Operational Mode Commands for CoS 3271 Copyright 2010 Juniper Networks Inc ...
Page 3435: ...CHAPTER 120 Operational Mode Commands for PoE 3339 Copyright 2010 Juniper Networks Inc ...
Page 3529: ...CHAPTER 126 Operational Mode Commands for MPLS 3433 Copyright 2010 Juniper Networks Inc ...