NOTE:
Access interfaces on EX2200, EX3200, EX4200, and EX4500 switches
are set to family ethernet-switching by default. You might have to delete this
or another user-configured family setting before changing the setting to
family inet
or family inet6.
Related
Documentation
Configuring Gigabit Ethernet Interfaces (J-Web Procedure) on page 1143
•
•
Monitoring Interface Status and Traffic on page 1167
•
show interfaces ge- on page 1245
•
show interfaces xe- on page 1262
•
Understanding Interface Naming Conventions on EX Series Switches on page 1097
Setting the Mode on an SFP+ Uplink Module (CLI Procedure)
SFP+ uplink modules are supported on EX3200 and EX4200 switches. You can use these
uplink modules either for two SFP+ transceivers or four SFP transceivers. You configure
the operating mode on the module to match the type of transceiver you want to use—that
is, for SFP+ transceivers, you configure the 10-gigabit operating mode, and for SFP
transceivers, you configure the 1-gigabit operating mode.
By default, the SFP+ uplink module operates in the 10-gigabit mode and supports only
SFP+ transceivers. If you have not changed the module from the default setting and you
want to use SFP+ transceivers, you do not need to configure the operating mode.
To set the operating mode of an SFP+ uplink module:
1.
Change the operating mode to the appropriate mode for the transceiver type you
want to use by using one of the following commands:
[edit]
user@switch#
set chassis fpc 0 pic 1 sfpplus pic-mode 1g
[edit]
user@switch#
set chassis fpc 0 pic 1 sfpplus pic-mode 10g
2.
If the switch is running:
•
Junos OS Release 10.1 or later, the changed operating mode takes effect immediately
unless a port on the SFP+ uplink module is a Virtual Chassis port (VCP). If any port
on the SFP+ uplink module is a VCP, the changed operating mode does not take
effect until the next reboot of the switch.
NOTE:
During the operating mode change, the Packet Forwarding Engine
is restarted. In a Virtual Chassis configuration, this means that the
Flexible PIC Concentrator connection with the master is dropped and
then reconnected.
Copyright © 2010, Juniper Networks, Inc.
1156
Complete Software Guide for Junos
®
OS for EX Series Ethernet Switches, Release 10.3
Summary of Contents for JUNOS OS 10.3 - SOFTWARE
Page 325: ...CHAPTER 17 Operational Mode Commands for System Setup 229 Copyright 2010 Juniper Networks Inc ...
Page 1323: ...CHAPTER 56 Operational Mode Commands for Interfaces 1227 Copyright 2010 Juniper Networks Inc ...
Page 2841: ...CHAPTER 86 Operational Commands for 802 1X 2745 Copyright 2010 Juniper Networks Inc ...
Page 3367: ...CHAPTER 113 Operational Mode Commands for CoS 3271 Copyright 2010 Juniper Networks Inc ...
Page 3435: ...CHAPTER 120 Operational Mode Commands for PoE 3339 Copyright 2010 Juniper Networks Inc ...
Page 3529: ...CHAPTER 126 Operational Mode Commands for MPLS 3433 Copyright 2010 Juniper Networks Inc ...