1/1 Configured 3 Up 10000 1 vcp-255/1/1
fpc4:
--------------------------------------------------------------------------
Interface Type Trunk Status Speed Neighbor
or ID (mbps) ID Interface
PIC / Port
vcp-0 Dedicated 1 Down 32000
vcp-1 Dedicated 2 Down 32000
0/20 Configured 3 Up 1000 0 vcp-255/1/2
0/21 Configured 3 Up 1000 0 vcp-255/1/3
Meaning
The dedicated VCPs are displayed as
vcp-0
and
vcp-1
. The uplink module interfaces that
have been set as uplink VCPs are displayed as
1/0
,
1/1
,
1/2
, and
1/3
. The EX4200-24F
network interfaces that have been set as VCPs are displayed as
0/20
and
0/21
. The
neighbor interface names of uplink and network VCPs are of the form
vcp-255/pic/port
—for example,
vcp-255/1/0
. In that name,
vcp-255
indicates that the
interface is a VCP,
1
is the uplink PIC number, and
0
is the port number. The
fpc
number
is the same as the member ID. The trunk ID is a positive number ID assigned to the LAG
formed by the Virtual Chassis. If no LAG is formed, the value is
–1
.
Related
Documentation
Monitoring Virtual Chassis Configuration Status and Statistics on page 1041
•
•
Configuring a Virtual Chassis (CLI Procedure) on page 1011
•
Configuring a Virtual Chassis (J-Web Procedure) on page 1015
•
Example: Configuring a Virtual Chassis Interconnected Across Multiple Wiring Closets
on page 963
Monitoring Virtual Chassis Configuration Status and Statistics
Purpose
Use the monitoring functionality to view the following information about Virtual Chassis
members and ports:
•
Member details and how members are connected with each other.
•
Traffic statistics for Virtual Chassis ports of the selected members.
•
Details of the Virtual Chassis port packet counters.
Action
To view Virtual Chassis monitoring details in the J-Web interface, select
Monitor > Virtual
Chassis
.
To view member details for all members in the CLI, enter the following command:
show virtual-chassis status
To view Virtual Chassis port traffic statistics for a specific member in the CLI, enter the
following command:
show virtual-chassis vc-port statistics member member-id
1041
Copyright © 2010, Juniper Networks, Inc.
Chapter 46: Verifying Virtual Chassis Configuration
Summary of Contents for JUNOS OS 10.3 - SOFTWARE
Page 325: ...CHAPTER 17 Operational Mode Commands for System Setup 229 Copyright 2010 Juniper Networks Inc ...
Page 1323: ...CHAPTER 56 Operational Mode Commands for Interfaces 1227 Copyright 2010 Juniper Networks Inc ...
Page 2841: ...CHAPTER 86 Operational Commands for 802 1X 2745 Copyright 2010 Juniper Networks Inc ...
Page 3367: ...CHAPTER 113 Operational Mode Commands for CoS 3271 Copyright 2010 Juniper Networks Inc ...
Page 3435: ...CHAPTER 120 Operational Mode Commands for PoE 3339 Copyright 2010 Juniper Networks Inc ...
Page 3529: ...CHAPTER 126 Operational Mode Commands for MPLS 3433 Copyright 2010 Juniper Networks Inc ...