Table 179: show interfaces diagnostics optics Output Fields
(continued)
Field Description
Field Name
Displays the voltage, in Volts.
Module voltage
(Not available for XFP transceivers)
Displays the laser received optical power, in milliwatts (mW) and decibels
referred to 1.0 mW (dBm).
Laser rx power
(Not available for SFP and SFP+ transceivers)
Displays the receiver signal average optical power, in milliwatts (mW)
and decibels referred to 1.0 mW (dBm).
Receiver signal average optical power
(Not available for XFP transceivers)
Displays whether the laser bias power setting high alarm is
On
or
Off
.
Laser bias current high alarm
Displays whether the laser bias power setting low alarm is
On
or
Off
.
Laser bias current low alarm
Displays whether the laser bias power setting high warning is
On
or
Off
.
Laser bias current high warning
Displays whether the laser bias power setting low warning is
On
or
Off
.
Laser bias current low warning
Displays whether the laser output power high alarm is
On
or
Off
.
Laser output power high alarm
Displays whether the laser output power low alarm is
On
or
Off
.
Laser output power low alarm
Displays whether the laser output power high warning is
On
or
Off
.
Laser output power high warning
Displays whether the laser output power low warning is
On
or
Off
.
Laser output power low warning
Displays whether the module temperature high alarm is
On
or
Off
.
Module temperature high alarm
Displays whether the module temperature low alarm is
On
or
Off
.
Module temperature low alarm
Displays whether the module temperature high warning is
On
or
Off
.
Module temperature high warning
Displays whether the module temperature low warning is
On
or
Off
.
Module temperature low warning
Displays whether the module voltage high alarm is
On
or
Off
.
Module voltage high alarm
(Not available for XFP transceivers)
Displays whether the module voltage low alarm is
On
or
Off
.
Module voltage low alarm
(Not available for XFP transceivers)
Displays whether the module voltage high warning is
On
or
Off
.
Module voltage high warning
(Not available for XFP transceivers)
1239
Copyright © 2010, Juniper Networks, Inc.
Chapter 56: Operational Mode Commands for Interfaces
Summary of Contents for JUNOS OS 10.3 - SOFTWARE
Page 325: ...CHAPTER 17 Operational Mode Commands for System Setup 229 Copyright 2010 Juniper Networks Inc ...
Page 1323: ...CHAPTER 56 Operational Mode Commands for Interfaces 1227 Copyright 2010 Juniper Networks Inc ...
Page 2841: ...CHAPTER 86 Operational Commands for 802 1X 2745 Copyright 2010 Juniper Networks Inc ...
Page 3367: ...CHAPTER 113 Operational Mode Commands for CoS 3271 Copyright 2010 Juniper Networks Inc ...
Page 3435: ...CHAPTER 120 Operational Mode Commands for PoE 3339 Copyright 2010 Juniper Networks Inc ...
Page 3529: ...CHAPTER 126 Operational Mode Commands for MPLS 3433 Copyright 2010 Juniper Networks Inc ...