Four EX4200-24P switches (SWA-2, SWA-3, SWA-4, and SWA-5) with 24 access
ports, all of which support PoE
Figure 18 on page 959 shows that all the member switches are interconnected with the
dedicated VCPs on the rear panel. The LCD on the front displays the member ID and role.
Figure 18: Default Configuration of Multimember Virtual Chassis in a Single
Wiring Closet
Configuration
Configure a multimember Virtual Chassis access switch in a single wiring closet using
the factory defaults:
CLI Quick
Configuration
By default, after you interconnect the switches with the dedicated VCPs and power on
the switches, the VCPs are operational. The mastership priorities and member IDs are
assigned by the software. To determine which switch has been selected as the master,
check the LCD on the front panel. It should be the first switch that you power on. The
backup should be the second switch that you power on. The other switches are all
linecards. Wait at least one minute after powering on the master, before continuing to
power on the other switches.
Step-by-Step
Procedure
To configure a multimember Virtual Chassis with default role assignments:
1.
Make sure the dedicated VCPs on the rear panel are properly cabled. See Virtual
Chassis Cabling Configuration Examples for EX4200 Switches for additional
information.
2.
Power on the switch that you want to function as the master (SWA-0). This
examples uses one of the larger switches (EX4200-48P) as the master.
3.
Check the front panel LCD to confirm that the switch has powered on correctly and
that a member ID has been assigned.
959
Copyright © 2010, Juniper Networks, Inc.
Chapter 44: Virtual Chassis—Configuration Examples
Summary of Contents for JUNOS OS 10.3 - SOFTWARE
Page 325: ...CHAPTER 17 Operational Mode Commands for System Setup 229 Copyright 2010 Juniper Networks Inc ...
Page 1323: ...CHAPTER 56 Operational Mode Commands for Interfaces 1227 Copyright 2010 Juniper Networks Inc ...
Page 2841: ...CHAPTER 86 Operational Commands for 802 1X 2745 Copyright 2010 Juniper Networks Inc ...
Page 3367: ...CHAPTER 113 Operational Mode Commands for CoS 3271 Copyright 2010 Juniper Networks Inc ...
Page 3435: ...CHAPTER 120 Operational Mode Commands for PoE 3339 Copyright 2010 Juniper Networks Inc ...
Page 3529: ...CHAPTER 126 Operational Mode Commands for MPLS 3433 Copyright 2010 Juniper Networks Inc ...