Table 179: show interfaces diagnostics optics Output Fields
(continued)
Field Description
Field Name
Displays the vendor-specified threshold for the laser bias current low
alarm.
Laser bias current low alarm threshold
Displays the vendor-specified threshold for the laser bias current high
warning.
Laser bias current high warning threshold
Displays the vendor-specified threshold for the laser bias current low
warning.
Laser bias current low warning threshold
Displays the vendor-specified threshold for the laser output power high
alarm.
Laser output power high alarm threshold
Displays the vendor-specified threshold for the laser output power low
alarm.
Laser output power low alarm threshold
Displays the vendor-specified threshold for the laser output power high
warning.
Laser output power high warning threshold
Displays the vendor-specified threshold for the laser output power low
warning.
Laser output power low warning threshold
Displays the vendor-specified threshold for the module temperature high
alarm.
Module temperature high alarm threshold
Displays the vendor-specified threshold for the module temperature low
alarm.
Module temperature low alarm threshold
Displays the vendor-specified threshold for the module temperature high
warning.
Module temperature high warning threshold
Displays the vendor-specified threshold for the module temperature low
warning.
Module temperature low warning threshold
Displays the vendor-specified threshold for the module voltage high
alarm.
Module voltage high alarm threshold
(Not available for XFP transceivers)
Displays the vendor-specified threshold for the module voltage low
alarm.
Module voltage low alarm threshold
(Not available for XFP transceivers)
Displays the vendor-specified threshold for the module voltage high
warning.
Module voltage high warning threshold
(Not available for XFP transceivers)
Displays the vendor-specified threshold for the module voltage low
warning.
Module voltage low warning threshold
(Not available for XFP transceivers)
Displays the vendor-specified threshold for the laser rx power high alarm.
Laser rx power high alarm threshold
1241
Copyright © 2010, Juniper Networks, Inc.
Chapter 56: Operational Mode Commands for Interfaces
Summary of Contents for JUNOS OS 10.3 - SOFTWARE
Page 325: ...CHAPTER 17 Operational Mode Commands for System Setup 229 Copyright 2010 Juniper Networks Inc ...
Page 1323: ...CHAPTER 56 Operational Mode Commands for Interfaces 1227 Copyright 2010 Juniper Networks Inc ...
Page 2841: ...CHAPTER 86 Operational Commands for 802 1X 2745 Copyright 2010 Juniper Networks Inc ...
Page 3367: ...CHAPTER 113 Operational Mode Commands for CoS 3271 Copyright 2010 Juniper Networks Inc ...
Page 3435: ...CHAPTER 120 Operational Mode Commands for PoE 3339 Copyright 2010 Juniper Networks Inc ...
Page 3529: ...CHAPTER 126 Operational Mode Commands for MPLS 3433 Copyright 2010 Juniper Networks Inc ...