291
Appendix
General Engine-Module
Graupner
HoTT
Order No.
33610
General sensor for
Graupner
HoTT receivers and models with
combustion or electric motor:
2x temperature and voltage measurements with warning thresholds
•
for min. and max. voltage and min. and max. temperature
Single cell measurement with warning thresholds for min. voltage
•
Voltage, current and capacity measurement with warning thresholds
•
for min. and max. voltage, max. capacity and max. current
Programmable current limiting
•
Current limiting with shunt resistors 2 x 1 mOhm parallel = 0.5 mOhm
•
Rotational speed measurement and warning thresholds for min. and
•
max. rotational speed
Fuel measurement with warning thresholds in 25 % increments
•
(after software update).
Adjustable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, always
•
Adjustable warning repetition time: Always, 1, 2, 3, 4, 5 min, once
•
2x temperature selectively 0 to 120 °C or 200 °C and voltage
•
measurement up to 80 V DC
1x rotational speed measurement up to 100,000 rpm with a two-
•
blade propeller
1x speed controller/servo input, 1x rotational speed regulatio
•
n input, 1x speed controller/servo output for rotational speed
regulation
1x current, voltage and capacity measurement up to 40 A (pulse 1 s
•
up to 60 A) and up to 30 V
1x single cell monitoring for 2 - 6S lithium batteries (LiPo, LiIo, LiFe)
•
etc.; see www.graupner.de for the respective product
•
General Air-Module
Graupner
HoTT
Order No.
33611
General sensor for
Graupner
HoTT receivers and models with
combustion or electric motor:
Vario with altitude signals and ascend and descend signals and
•
additional warning thresholds for min. altitude, max. altitude, rate of
ascend and descend in two stages
Altitude display (-500 … +3000 m) and memory of the min. and max.
•
altitude.
2x temperature and voltage measurements with warning thresholds
•
for min. and max. voltage and min. and max. temperature
Single cell measurement with warning thresholds for min. voltage
•
Voltage, current and capacity measurement with warning thresholds
•
for min. and max. voltage, max. capacity and max. current
Rotational speed measurement with rotational speed regulation
•
(programmable) and warning thresholds for min. and max. rotational
speed
Fuel measurement with warning thresholds in 25 % increments.
•
Adjustable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, always
•
Adjustable warning repetition time: Always, 1, 2, 3, 4, 5 min, once
•
2x temperature selectively 0 to 120 °C or 200 °C and voltage
•
measurement up to 80 V DC
1x rotational speed measurement up to 100,000 rpm with a two-
•
blade propeller
1x speed controller/servo input, 1x rotational speed regulation input,
•
1x speed controller/servo output for rotational speed regulation
1x current and voltage and capacity measurement up to 40 A (pulse
•
1s: 60 A ) and up to 30 V
etc.; see www.graupner.de for the respective product
•
Electric Air-Module
Graupner
HoTT
Order No.
33620
General sensor for
Graupner
HoTT receiver and models with electric
motor
Vario with altitude signals, ascend and descend signals as well as
•
additional warning thresholds for min. altitude, max. altitude, rate of
ascend and descend in two stages
Altitude display (-500 … +3000 m) and memory of the min. and max.
•
altitude.
2x temperature and voltage measurements with warning thresholds
•
for min. and max. voltage and min. and max. temperature
Single cell measurement 2 ... 14S with warning thresholds for min.
•
voltage
Voltage, current and capacity measurement with warning thresholds
•
for min. and max. voltage, max. capacity and max. current
Adjustable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, always
•
Adjustable warning repetition time: Always, 1, 2, 3, 4, 5 min, once
•
2x temperature selectively 0 to 120 °C or 200 °C and voltage
•
measurement up to 80 V DC
1x speed controller input, 1x speed controller output for single cell
•
undervoltage correction
1x current and voltage and capacity measurement up to 150 A
•
(short-term 1 sec 320 A) and up to 60 V
1x single cell monitoring for 2 - 14S lithium batteries (LiPo, LiIo, LiFe)
•
1x telemetry connection for receiver
•
Summary of Contents for mx-20 Hott
Page 41: ...41 Your notes...
Page 49: ...49 Your notes...
Page 55: ...55 Your notes...
Page 81: ...81 Your notes...
Page 85: ...85 Your notes...
Page 89: ...89 Your notes...
Page 99: ...99 Detail program description Control adjust...
Page 127: ...127 Detail program description Control adjust...
Page 131: ...131 Detail program description Control adjust...
Page 163: ...163 Detail program description Control adjust...
Page 191: ...191 Detail program description Control adjust...
Page 207: ...207 Detail program description Control adjust...
Page 228: ...228 Detail program description Control adjust...
Page 229: ...229 Detail program description Control adjust...
Page 251: ...251 Detail program description Control adjust...