Transmitter description - Telemetry data display
VARIO
RXSQ
0
MAX
0m
MIN
0m
ALT
0
H
L
m/1s
0.0
m/3s
0.0
m/10s
0.0
If attached to the receiver, this screen will display the
data acquired by a Vario module, Order No.
33601
.
The displayed items are as follows:
Value
Explanation
ALT
current altitude
RXSQ
Signal strength of the signal received
by the receiver in %, see page 209.
MAX
the preset maximum altitude limit
relative to starting location at which,
when exceeded, will cause an audible
warning to be sounded
MIN
the preset minimum altitude limit
relative to the starting location at
which, when underrun, will cause an
audible warning to be sounded
m/1 s
m/1 s ascent/decent rate
m/3 s
m/3 s ascent/decent rate
m/10 s
m/10 s ascent/decent rate
ELECTRIC AIR MODULE
0.0V 0m/3s
BAT1 0m/1s
BAT2
0.0V T2 0°C
T1 0°C
0
1L0.00
2L0.00
3L0.00
4L0.00
5L0.00
6L0.00
ALT 0m
7L0.00
0.0V 0A
0.0V 0m/3s
BAT1 0m/1s
BAT2
0.0V T2 0°C
T1 0°C
0
1H0.00
2H0.00
3H0.00
4H0.00
5H0.00
6H0.00
ALT 0m
7H0.00
0.0V 0A
If attached to the receiver, this screen will display
the data acquired by an Electric-Air module, Order
No.
33620
. More details about this module can be found
in the appendix or in Internet at www.graupner.de in the
web page for the given product.
Depending on how this module is equipped with
sensors, this screen can permanently display the data
shown in the adjacent table.
The current voltage of up to two batteries (BAT1 and
BAT2), up to two temperature measurements (T1 and
T2), current altitude with respect to the starting location,
the model's ascent/decent rate in m/1 s and m/3 s and,
in the middle of the screen, the current draw currently
being taken from a power source.
Along the right edge of the screen is a table of
alternating values for cell voltages at balancer
connections (L) or voltages for up to 7 attached battery
cell packs (H).
The displayed items are as follows:
Value
Explanation
V
current voltage
A
current current
BAT1 / BAT2
battery 1 or 2
ALT
current altitude
m/1 s
m/1 s ascent/decent rate
m/3 s
m/3 s ascent/decent rate
T1 / T2
temperature of sensor 1 or 2
L or H
cell voltage of cells 1 … 14 (14 max)
L = balancer connection 1
H = balancer connection 2
GENERAL MODULE
0.0V
BAT1
BAT2
0.0V T2 0°C
T1 0°C
E FUEL F
CELL V
1:0.00
2:0.00
3:0.00
4:0.00
5:0.00
6:0.00
0
0.0V
BAT1
BAT2
0.0V T2 0°C
T1 0°C
E FUEL F
ALT
0m
0m1
0m3
0.0A
POWER
0.0V
0
If attached to the receiver, this screen will display the
data acquired by a General-Engine module, Order
No.
33601
, or a General-Air module, Order No.
33611
.
More details about these modules can be found in the
Summary of Contents for mx-20 Hott
Page 41: ...41 Your notes...
Page 49: ...49 Your notes...
Page 55: ...55 Your notes...
Page 81: ...81 Your notes...
Page 85: ...85 Your notes...
Page 89: ...89 Your notes...
Page 99: ...99 Detail program description Control adjust...
Page 127: ...127 Detail program description Control adjust...
Page 131: ...131 Detail program description Control adjust...
Page 163: ...163 Detail program description Control adjust...
Page 191: ...191 Detail program description Control adjust...
Page 207: ...207 Detail program description Control adjust...
Page 228: ...228 Detail program description Control adjust...
Page 229: ...229 Detail program description Control adjust...
Page 251: ...251 Detail program description Control adjust...