231
Detail program description - Control adjust
Servo test
Function test of Servo 1 … 8
Scroll with the arrow keys of the left or right touch pad to
the menu item "
Servo test
" of the multifunction menu:
Telemetr y
info display
Basic settings
Ser vo display
Code lock
Ser vo test
By briefl y pressing the central
SET
key of the right touch
pad, this menu item opens:
SERVO TEST
act
off
1 2 3 4 5 6 7 8
0.5s
Any of the inputs 1 ... 8 can be activated for the servo
test by selecting with the arrow keys of the left or right
touch pad and then briefl y pressing
SET
key of the right
touch pad. As soon as you have set only one of the
inputs 1 ... 8 to "active", the following notice appears at
the bottom of the display screen:
1 2 3 4 5 6 7 8
0.5s
CLR=act./deact.
SERVO TEST
act
off
Simultaneously pressing the arrow keys
or
of
the right touch pad (
CLEAR
) would now start and stop
the servo test for input "1", fo r example, with a cycle
time of 0.5 s.
To change the cycle time, select the time input fi eld
with the arrow keys of the left or right touch pad. After
activation of the input fi eld by briefl y pressing the central
SET
key of the right touch pad, the movement cycle
can be changed in 0.5 s increments between 0.5 s and
3.0 s using the arrow keys of the left or right touch pad.
Briefl y pressing the central
ESC
of the left touch pad or
the central
SET
key of the right touch pad completes the
time presetting.
1 2 3 4 5 6 7 8
3.0s
HLD = aktivier t
SERVO TEST
act
off
The "servo test" function started by simultaneously
pressing the arrow keys
or
of the right touch
pad (
CLEAR
) automatically control all servos as though
the would simultaneously and permanently move the
corresponding control back and forth between -100
% and +100 % in the set time. All active mixing and
coupling functions in the respective model memory,
therefore, are effective and the servos move within the
specifi ed servo paths and servo delimitations.
As soon as you have started the servo test by
simultaneously pressing the arrow keys
or
of
the right touch pad (
CLEAR
), a window opens:
1 2 3 4 5 6 7 8
3.0s
CLR=act./deact.
Ser vo test act.
SERVO TEST
act
off
Simultaneously press the arrow keys
or
of
the right touch pad (
CLEAR
) in order to end the test.
Important notice:
The shut-off of the transmitter does not
automatically end an active servo test. Therefore,
always stop a servo test manually BEFORE
SHUTTING OFF the transmitter, because the servo
test is otherwise restarted after switching on the
transmitter again.
Summary of Contents for mx-20 Hott
Page 41: ...41 Your notes...
Page 49: ...49 Your notes...
Page 55: ...55 Your notes...
Page 81: ...81 Your notes...
Page 85: ...85 Your notes...
Page 89: ...89 Your notes...
Page 99: ...99 Detail program description Control adjust...
Page 127: ...127 Detail program description Control adjust...
Page 131: ...131 Detail program description Control adjust...
Page 163: ...163 Detail program description Control adjust...
Page 191: ...191 Detail program description Control adjust...
Page 207: ...207 Detail program description Control adjust...
Page 228: ...228 Detail program description Control adjust...
Page 229: ...229 Detail program description Control adjust...
Page 251: ...251 Detail program description Control adjust...