HI
-
700HS service manual
-
2
-
component parts
2
-
19 Issue 1 02/2020
MAD11 analogue unit
Refer to the electrical drawings for more details on the connection to and from this unit.
Not
used
The final speed of the conveyors is controlled by the output voltage from CN2; therefore this voltage is
variable depending on the conveyor speed selected.
The range the voltage will be is between 1v and 5v (1v being slowest speed, 5v being max speed)
This voltage is connected to each motor speed control board at VRM (black v
-
) and VRL (orange v+).
To Motor speed control boards
Black to VRM (v
-
)
Orange to VRL (v+)
B
lack
B
lack
B
lack
B
lack
Outputs runs through a
potentiometer for each
conveyor to set speed at
build stage only. Not
used after initial setup
Rejector signal output
If a rejector is to be connected to the HI
-
HS, there are three outputs from the PLC each having a 2 way
Molex connector fitted. The connectors are marked as REJ 1, REJ 2 & REJ 3.
Remove this
trunking cover
REJ 1, REJ 2 & REJ 3 are
located here
Summary of Contents for HI-700HS
Page 1: ...HI 700HS service manual Issue 2 06 2020 HI 700HS Service manual...
Page 98: ...HI 700HS service manual 2 component parts 2 64 Issue 1 02 2020 HS blow applicator Pneumatics...
Page 238: ...HI 700HS service manual 4 servicing 4 129 Issue 2 06 2020 Side labeller applicator Pneumatics...
Page 270: ...Main electrical cabinet P5 2...
Page 271: ...Main electrical cabinet P5 3...
Page 272: ...Main electrical cabinet display enclosure P5 4...
Page 273: ...Single Servo indexer contol box P5 5...
Page 274: ...Single Servo indexer control box P5 6...
Page 275: ...Triple Servo indexer control box P5 7...
Page 276: ...Triple servo indexer control box P5 8...
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ...Low voltage 24v power lift P5 13...
Page 282: ...240v power lift P5 14...
Page 283: ...240v power lift P5 15...
Page 288: ...P5 20 15 touch screen assembly not HS style...
Page 289: ......