HI
-
700HS service manual
-
4 –
servicing
4
-
97 Issue 2 06/2020
HS blow applicator setup continued
-
Software settings
(Worldview)
When using the HS blow applicator, use the following software settings
Go to Service menu / Labeller setup / service
Settings tab
Applicator type = Airbox
Applicator Time = 20ms (this is the amount of time the air jets blow
for). This value may change depending on label size but should not
be too long (more than 60ms) as excess air can create label
placement inaccuracy.
Note: if any changes are made on this page, ensure the
button is pressed to store new setting before using the
application test
Debug tab
Use the Application test feature to test the applicator set up.
Touch this option to continually feed and blow labels down (conveyors
not running) to check applicator operation.
Use the settings above to adjust the application speed of operation for
this application test
Use the application test function to check the feed and apply operation of the applicator
Summary of Contents for HI-700HS
Page 1: ...HI 700HS service manual Issue 2 06 2020 HI 700HS Service manual...
Page 98: ...HI 700HS service manual 2 component parts 2 64 Issue 1 02 2020 HS blow applicator Pneumatics...
Page 238: ...HI 700HS service manual 4 servicing 4 129 Issue 2 06 2020 Side labeller applicator Pneumatics...
Page 270: ...Main electrical cabinet P5 2...
Page 271: ...Main electrical cabinet P5 3...
Page 272: ...Main electrical cabinet display enclosure P5 4...
Page 273: ...Single Servo indexer contol box P5 5...
Page 274: ...Single Servo indexer control box P5 6...
Page 275: ...Triple Servo indexer control box P5 7...
Page 276: ...Triple servo indexer control box P5 8...
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ...Low voltage 24v power lift P5 13...
Page 282: ...240v power lift P5 14...
Page 283: ...240v power lift P5 15...
Page 288: ...P5 20 15 touch screen assembly not HS style...
Page 289: ......