HI
-
700HS service manual
-
4 –
servicing
4
-
43 Issue 2 06/2020
Pack sensor adjustment
-
opto electric (Wenglor)
In electrical cabinet, each pack sensor cable connects to a 3 way Molex connector. Linked to this connector
is another Molex connector with a single wire connection. This wire is the Teach wire.
To allow sensitivity adjustment (teach mode) this connector needs to be disconnected.
Selecting a teach
-
in mode
The standard mode used for the 700 series machines is when the LED flashes 4 times
Normally, the required mode is already set and the sensor is ready to sense clear packs. If sensing
problems occur with customer pack, the sensor can be re
-
trained.
Press and hold the Teach button on the sensor for at least 10 seconds until the LED switches from rapid to
slow blinking. In this mode (slow blinking) the teach
-
in mode type can be selected
.
By pressing the teach button again the mode will be changed (1 blink, 2 blinks etc.)
After the button has not been activated for 15 seconds, the sensor returns automatically to the normal
display mode.
Teach modes
Blinking
Normally closed /
normally open
TEACH Mode
1x
NO
Normal teach in
2x
Minimal teach in
3x
Normal teach in
NC
4x
Minimal teach in
Ensure sensor is set to this mode
LED
Teach button
Once the teach wire has been disconnected, the
sensor can be set
Press and hold the Teach button on the sensor
for at least 1 second until the LED starts to blink
rapidly
The switching threshold is taught when the
button is released. The switching threshold is set
to maximum sensitivity.
Re
-
connect teach wire to prevent further
adjustment. On re
-
connection, the LED will flash
and run through a set of flashes (5 sets of 4
pulses).
Teach wire connection
Summary of Contents for HI-700HS
Page 1: ...HI 700HS service manual Issue 2 06 2020 HI 700HS Service manual...
Page 98: ...HI 700HS service manual 2 component parts 2 64 Issue 1 02 2020 HS blow applicator Pneumatics...
Page 238: ...HI 700HS service manual 4 servicing 4 129 Issue 2 06 2020 Side labeller applicator Pneumatics...
Page 270: ...Main electrical cabinet P5 2...
Page 271: ...Main electrical cabinet P5 3...
Page 272: ...Main electrical cabinet display enclosure P5 4...
Page 273: ...Single Servo indexer contol box P5 5...
Page 274: ...Single Servo indexer control box P5 6...
Page 275: ...Triple Servo indexer control box P5 7...
Page 276: ...Triple servo indexer control box P5 8...
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ...Low voltage 24v power lift P5 13...
Page 282: ...240v power lift P5 14...
Page 283: ...240v power lift P5 15...
Page 288: ...P5 20 15 touch screen assembly not HS style...
Page 289: ......