HI
-
700HS service manual
-
4 –
servicing
4
-
149 Issue 2 06/2020
6.
Measure between the
end of the scale deck
and the extra sensor
7.
Insert that measurement into the Extra Sensor distance and click the save button
8.
Run another pack down the line. The pack should be labelled in the same place with no errors.
9.
If you find that the label is slightly out of position as shown below, you may need to adjust the extra
sensor distance slightly (set in step 7) to get it back to the correct spot. In this case reduce it from
100 to 90
10.
Make sure a suitable window is set for the speed of the machine using the guide on the following
page. If you need to change remember to click the save button
Summary of Contents for HI-700HS
Page 1: ...HI 700HS service manual Issue 2 06 2020 HI 700HS Service manual...
Page 98: ...HI 700HS service manual 2 component parts 2 64 Issue 1 02 2020 HS blow applicator Pneumatics...
Page 238: ...HI 700HS service manual 4 servicing 4 129 Issue 2 06 2020 Side labeller applicator Pneumatics...
Page 270: ...Main electrical cabinet P5 2...
Page 271: ...Main electrical cabinet P5 3...
Page 272: ...Main electrical cabinet display enclosure P5 4...
Page 273: ...Single Servo indexer contol box P5 5...
Page 274: ...Single Servo indexer control box P5 6...
Page 275: ...Triple Servo indexer control box P5 7...
Page 276: ...Triple servo indexer control box P5 8...
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ...Low voltage 24v power lift P5 13...
Page 282: ...240v power lift P5 14...
Page 283: ...240v power lift P5 15...
Page 288: ...P5 20 15 touch screen assembly not HS style...
Page 289: ......