HI
-
700HS service manual
-
4 –
servicing
4
-
62 Issue 2 06/2020
Signature labeller
-
thermal head horizontal position
Head set up position
-
wear strip type & platen roller
The head mounting plate (701
-
0021) which is fixed to the labeller back plate with four hex head screws
has a default position which then allows for correct fine horizontal adjustment on the two adjuster screws
NOTE: before setting the head mount plate position, the thermal head horizontal position should
be set using the two adjuster screws to its default position
-
see below
Set the thermal head horizontal position to its
default position by turning in/out the two
adjuster screws circled above
The default position is when the two top edges of
the two brackets (head adjustment block & head
mounting bracket) are in line, see circled area
left
This should be equal on both adjuster screws
Summary of Contents for HI-700HS
Page 1: ...HI 700HS service manual Issue 2 06 2020 HI 700HS Service manual...
Page 98: ...HI 700HS service manual 2 component parts 2 64 Issue 1 02 2020 HS blow applicator Pneumatics...
Page 238: ...HI 700HS service manual 4 servicing 4 129 Issue 2 06 2020 Side labeller applicator Pneumatics...
Page 270: ...Main electrical cabinet P5 2...
Page 271: ...Main electrical cabinet P5 3...
Page 272: ...Main electrical cabinet display enclosure P5 4...
Page 273: ...Single Servo indexer contol box P5 5...
Page 274: ...Single Servo indexer control box P5 6...
Page 275: ...Triple Servo indexer control box P5 7...
Page 276: ...Triple servo indexer control box P5 8...
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ...Low voltage 24v power lift P5 13...
Page 282: ...240v power lift P5 14...
Page 283: ...240v power lift P5 15...
Page 288: ...P5 20 15 touch screen assembly not HS style...
Page 289: ......