700HS service manual
-
4 –
servicing
4
-
36 Issue 2 06/2020
Calibrate zero & span
Use this function to calibrate the scale.
Note: before starting this process, ensure the span weight value is known and suitable calibrated weights
are available.
Ensure the scale capacity options are set correctly
To calibrate the machine, touch the calibrate zero & span button and follow the onscreen instructions.
Wait for the on
-
screen instruction to:
•
Clear scale,
(ensure scale is completely clean with nothing resting on it)
•
Load span weight,
(place the pre
-
determined calibration weight on the scale)
•
Span complete.
(this will take a few moments to appear, lift weights off scale, press OK,)
•
Once this has been done, the calibration is complete.
When exiting the scale mode the settings are saved.
On exiting the scale settings the ADC security switch will need to be re
-
set back to ON.
Sub span
For sub spanning instruction within Console software refer to the 700/800 series operation manual / service
menu section
1
2
3
Summary of Contents for HI-700HS
Page 1: ...HI 700HS service manual Issue 2 06 2020 HI 700HS Service manual...
Page 98: ...HI 700HS service manual 2 component parts 2 64 Issue 1 02 2020 HS blow applicator Pneumatics...
Page 238: ...HI 700HS service manual 4 servicing 4 129 Issue 2 06 2020 Side labeller applicator Pneumatics...
Page 270: ...Main electrical cabinet P5 2...
Page 271: ...Main electrical cabinet P5 3...
Page 272: ...Main electrical cabinet display enclosure P5 4...
Page 273: ...Single Servo indexer contol box P5 5...
Page 274: ...Single Servo indexer control box P5 6...
Page 275: ...Triple Servo indexer control box P5 7...
Page 276: ...Triple servo indexer control box P5 8...
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ...Low voltage 24v power lift P5 13...
Page 282: ...240v power lift P5 14...
Page 283: ...240v power lift P5 15...
Page 288: ...P5 20 15 touch screen assembly not HS style...
Page 289: ......