HI
-
700HS service manual
-
4 –
servicing
4
-
152 Issue 2 06/2020
Option part
-
Barcode scanner (Keyence)
If the Keyence type barcode scanner (BL
-
1300) is fitted to the HI
-
HS , the following details the DIGI
Console software setup and Scanner set.
The setting of the trigger sensor for the scanner is done in the normal way for the Wenglor type sensors,
refer to this service section (4) for Wenglor setup details. The Wenglor teach wire connection can be found
in the Scanner electrical box at the rear of the machine.
Console software settings
Service menu / internal/external devices
-
Control
Serial port settings:
Serial port
-
this must match the Port used on the PC main board for the scanner connection.
Ensure Baud rate, Parity, Number of data bits & Number of stop bits are set to the values as shown above.
Start parameters:
Rejector delay (800)
-
Rejecter pulse length (350)
-
Pack sensor debounce (100)
-
Bad input 1 debounce (100)
-
Bad input 2 debounce (100)
-
Label seen debounce (100)
-
Barcode bad window (20)
-
Trigger to barcode scanners (120)
-
Summary of Contents for HI-700HS
Page 1: ...HI 700HS service manual Issue 2 06 2020 HI 700HS Service manual...
Page 98: ...HI 700HS service manual 2 component parts 2 64 Issue 1 02 2020 HS blow applicator Pneumatics...
Page 238: ...HI 700HS service manual 4 servicing 4 129 Issue 2 06 2020 Side labeller applicator Pneumatics...
Page 270: ...Main electrical cabinet P5 2...
Page 271: ...Main electrical cabinet P5 3...
Page 272: ...Main electrical cabinet display enclosure P5 4...
Page 273: ...Single Servo indexer contol box P5 5...
Page 274: ...Single Servo indexer control box P5 6...
Page 275: ...Triple Servo indexer control box P5 7...
Page 276: ...Triple servo indexer control box P5 8...
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ...Low voltage 24v power lift P5 13...
Page 282: ...240v power lift P5 14...
Page 283: ...240v power lift P5 15...
Page 288: ...P5 20 15 touch screen assembly not HS style...
Page 289: ......