Signature labeller
-
air cylinder position on head assembly
With the thermal head in its locked down position there should be a small gap (approx. 1mm) between the
cylinder rod end cap and the head adjustment block
Small gap (approx. 1mm) in
this position
With the thermal head in its locked down position,
loosen the large nut at the top of the air cylinder
Screw the air cylinder down until it just touches the
head adjustment block then back off cylinder 1/2
turn to leave a small gap between rod end cap &
head adjustment block
With the air cylinder adjusted correctly, if the ther-
mal head is lifted as shown below there should be
a small amount (approx. 1mm) of movement up-
wards until it touches the rod end cap
Small gap
here after
adjusting
Summary of Contents for HI-700HS
Page 1: ...HI 700HS service manual Issue 2 06 2020 HI 700HS Service manual...
Page 98: ...HI 700HS service manual 2 component parts 2 64 Issue 1 02 2020 HS blow applicator Pneumatics...
Page 238: ...HI 700HS service manual 4 servicing 4 129 Issue 2 06 2020 Side labeller applicator Pneumatics...
Page 270: ...Main electrical cabinet P5 2...
Page 271: ...Main electrical cabinet P5 3...
Page 272: ...Main electrical cabinet display enclosure P5 4...
Page 273: ...Single Servo indexer contol box P5 5...
Page 274: ...Single Servo indexer control box P5 6...
Page 275: ...Triple Servo indexer control box P5 7...
Page 276: ...Triple servo indexer control box P5 8...
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ...Low voltage 24v power lift P5 13...
Page 282: ...240v power lift P5 14...
Page 283: ...240v power lift P5 15...
Page 288: ...P5 20 15 touch screen assembly not HS style...
Page 289: ......