HI
-
700HS service manual
-
4 –
servicing
4
-
37 Issue 2 06/2020
Electrical cabinet
-
ADC unit
If an ADC unit is needed to be replaced, any metrological data (i.e. –
capacity details, calibration, and
sub
-
span data) will all need to be re
-
entered,
(also see following page showing where data is stored).
To remove the ADC:
•
Un
-
clip load cell connection
•
Un
-
plug power supply connection at psu
•
Un
-
plug 9 way D
’
type connector plugged into main board (LV
-
67
-
P main board)
•
Un
-
plug 3 way Molex plug from main wiring loom
Un
-
screw the 4 mounting screws and remove ADC unit form machine
Replace with new unit and plug in the same 4 connections as above.
When the weighing machine is re
-
started, a
‘
Checksum mismatch
’
error is likely to appear.
Refer to page 4
-
39 for instructions on this error.
Load cell
connection
A/D unit with
front cover
on.
A/D power supply
connection
Serial comms connection to
main board. (via 9 way d
’
type
plug)
&
Sensor circuit from plc (3 way
Molex plug)
Summary of Contents for HI-700HS
Page 1: ...HI 700HS service manual Issue 2 06 2020 HI 700HS Service manual...
Page 98: ...HI 700HS service manual 2 component parts 2 64 Issue 1 02 2020 HS blow applicator Pneumatics...
Page 238: ...HI 700HS service manual 4 servicing 4 129 Issue 2 06 2020 Side labeller applicator Pneumatics...
Page 270: ...Main electrical cabinet P5 2...
Page 271: ...Main electrical cabinet P5 3...
Page 272: ...Main electrical cabinet display enclosure P5 4...
Page 273: ...Single Servo indexer contol box P5 5...
Page 274: ...Single Servo indexer control box P5 6...
Page 275: ...Triple Servo indexer control box P5 7...
Page 276: ...Triple servo indexer control box P5 8...
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ...Low voltage 24v power lift P5 13...
Page 282: ...240v power lift P5 14...
Page 283: ...240v power lift P5 15...
Page 288: ...P5 20 15 touch screen assembly not HS style...
Page 289: ......