HI
-
700HS service manual
-
4 –
servicing
4
-
112 Issue 2 06/2020
Maintenance of centralizer label reel
Central knob resistance adjustment
The resistance the centralizer adjustment knob has to
turn can be adjusted.
If the tension is too loose, the centralizer may not keep
its adjustment. If too tight, it may be difficult to turn.
Loosen the set screw recessed in the knob and remove
the knob
The central shaft and locknut are now visible
Using a spanner to hold the central shaft, adjust the
tightness of the lock nut.
Tightening the locknut will increase turning resistance.
Ensure when replacing the adjuster knob, the set screw
lines up with the flat on the central shaft.
Use Loctite 222 on set screw on re
-
assembly
Summary of Contents for HI-700HS
Page 1: ...HI 700HS service manual Issue 2 06 2020 HI 700HS Service manual...
Page 98: ...HI 700HS service manual 2 component parts 2 64 Issue 1 02 2020 HS blow applicator Pneumatics...
Page 238: ...HI 700HS service manual 4 servicing 4 129 Issue 2 06 2020 Side labeller applicator Pneumatics...
Page 270: ...Main electrical cabinet P5 2...
Page 271: ...Main electrical cabinet P5 3...
Page 272: ...Main electrical cabinet display enclosure P5 4...
Page 273: ...Single Servo indexer contol box P5 5...
Page 274: ...Single Servo indexer control box P5 6...
Page 275: ...Triple Servo indexer control box P5 7...
Page 276: ...Triple servo indexer control box P5 8...
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ...Low voltage 24v power lift P5 13...
Page 282: ...240v power lift P5 14...
Page 283: ...240v power lift P5 15...
Page 288: ...P5 20 15 touch screen assembly not HS style...
Page 289: ......