Related Information
Remote System Upgrade (ALTREMOTE_UPDATE) Megafunction User Guide
Remote System Upgrade Registers
Table 7-6: Remote System Upgrade Registers
Description
Register
Accessible by the logic array and clocked by
RU_CLK
.
•
Bits[4..0]
—Contents of the status register are shifted into these bits.
•
Bits[37..0]
—Contents of the update and control registers are shifted into
these bits.
Shift
This register is clocked by the 10-MHz internal oscillator. The contents of this
register are shifted to the shift register for the user logic in the application
configuration to read. When reconfiguration is triggered, this register is updated
with the contents of the update register.
Control
This register is clocked by
RU_CLK
. The factory configuration updates this register
by shifting data into the shift register and issuing an update. When reconfigura-
tion is triggered, the contents of the update register are written to the control
register.
Update
After each reconfiguration, the remote system upgrade circuitry updates this
register to indicate the event that triggered the reconfiguration. This register is
clocked by the 10-MHz internal oscillator.
Status
Related Information
•
on page 7-33
•
on page 7-33
Configuration, Design Security, and Remote System Upgrades in Cyclone V Devices
Altera Corporation
CV-52007
Remote System Upgrade Registers
7-32