![Altera Cyclone V Device Handbook Download Page 220](http://html1.mh-extra.com/html/altera/cyclone-v/cyclone-v_device-handbook_2910791220.webp)
The operating voltage for the configuration input pin is independent of the I/O banks power supply, V
CCIO
,
during configuration. Therefore, Cyclone V devices do not require configuration voltage constraints on
V
CCIO
.
V
CCPD
Pin
Use the V
CCPD
pin, a dedicated programming power supply, to power the I/O pre-drivers and JTAG I/O
pins (
TCK
,
TMS
,
TDI
, and
TDO
). The supported configuration voltages are 2.5, 3.0, and 3.3 V.
If V
CCIO
of the bank is set to 2.5 V or lower, V
CCPD
must be powered up at 2.5 V. If V
CCIO
is set greater than
2.5 V, V
CCPD
must be greater than V
CCIO
. For example, when V
CCIO
is set to 3.0 V, V
CCPD
must be set at
3.0 V or above. When V
CCIO
is set to 3.3 V, V
CCPD
must be set at 3.3 V.
Related Information
•
Provides more information about the ramp-up time specifications.
•
Cyclone V Device Family Pin Connection Guidelines
Provides more information about configuration pin connections.
•
on page 7-6
Provides more information about configuration pins.
•
I/O Standards Voltage Levels in Cyclone V Devices
on page 5-8
Provides more information about typical power supplies for each supported I/O standards in Cyclone V
devices.
Reset
POR delay is the time frame between the time when all the power supplies monitored by the POR circuitry
reach the recommended operating voltage and when
nSTATUS
is released high and the Cyclone V device is
ready to begin configuration.
Set the POR delay using the
MSEL
pins.
The user I/O pins are tied to an internal weak pull-up until the device is configured.
Related Information
•
on page 7-2
•
Provides more information about the POR delay specification.
Configuration
For more information about the
DATA[]
pins for each configuration scheme, refer to the appropriate
configuration scheme.
Configuration Error Handling
To restart configuration automatically, turn on the Auto-restart configuration after error option in the
General page of the Device and Pin Options dialog box in the Quartus II software.
Altera Corporation
Configuration, Design Security, and Remote System Upgrades in Cyclone V Devices
7-5
Reset
CV-52007