Related Information
Provides more information about the POR delay specification and t
RAMP
.
Power Supplies Monitored and Not Monitored by the POR Circuitry
Table 10-2: Power Supplies Monitored and Not Monitored by the Cyclone V POR Circuitry
Power Supplies Not Monitored
Power Supplies Monitored
• V
CCE_GXBL
• V
CCH_GXBL
• V
CCL_GXBL
• V
CCA_FPLL
• V
CCIO
• V
CCIO_HPS
• V
CCPLL_HPS
• V
CC_AUX
• V
CCBAT
• V
CC
• V
CCPD
• V
CCPGM
• V
CC_HPS
• V
CCPD_HPS
• V
CCRSTCLK_HPS
For the device to exit POR, you must power the V
CCBAT
power supply even if you do not use the
volatile key.
Note:
Related Information
•
Provides information from the Hard Processor System Technical Reference Manual.
•
Configuration, Design Security, and Remote System Upgrades in Cyclone V Devices
Provides more information about the
MSEL
pin settings for each POR delay.
Document Revision History
Changes
Version
Date
• Updated the note to the V
CCPD_HPS
power rail that current transient at
V
CCPD_HPS
is observed only when the recommended power-up sequence
is not followed. To avoid the current transient at V
CCPD_HPS
, follow the
recommended power-up sequence.
• Added Group 1 and Group 2 to the Power-Up Sequence.
2014.01.10
January 2014
• Added power-up sequences for Cyclone V SX, SE and ST devices.
• Added the current transient that occurs on HPS power rails during
power-up
2013.06.28
June 2013
• Added link to the known document issues in the Knowledge Base.
• Moved all links to the Related Information section of respective topics
for easy reference.
• Updated dynamic power in Power Consumption for improve clarity.
2013.05.06
May 2013
Altera Corporation
Power Management in Cyclone V Devices
10-7
Power Supplies Monitored and Not Monitored by the POR Circuitry
CV-52010
2014.01.10