![Altera Cyclone V Device Handbook Download Page 12](http://html1.mh-extra.com/html/altera/cyclone-v/cyclone-v_device-handbook_2910791012.webp)
Figure 1-2: LAB and MLAB Structure for Cyclone V Devices
MLAB
LAB
LUT-Based-32 x 2
Simple Dual-Port SRAM
LUT-Based-32 x 2
Simple Dual-Port SRAM
LUT-Based-32 x 2
Simple Dual-Port SRAM
LUT-Based-32 x 2
Simple Dual-Port SRAM
LUT-Based-32 x 2
Simple Dual-Port SRAM
LUT-Based-32 x 2
Simple Dual-Port SRAM
LUT-Based-32 x 2
Simple Dual-Port SRAM
LUT-Based-32 x 2
Simple Dual-Port SRAM
LUT-Based-32 x 2
Simple Dual-Port SRAM
LUT-Based-32 x 2
Simple Dual-Port SRAM
ALM
ALM
ALM
ALM
ALM
ALM
ALM
ALM
ALM
ALM
LAB Control Block
LAB Control Block
You can use an MLAB
ALM as a regular LAB
ALM or configure it as a
dual-port SRAM.
You can use an MLAB
ALM as a regular LAB
ALM or configure it as a
dual-port SRAM.
Local and Direct Link Interconnects
Each LAB can drive 30 ALMs through fast-local and direct-link interconnects. Ten ALMs are in any given
LAB and ten ALMs are in each of the adjacent LABs.
The local interconnect can drive ALMs in the same LAB using column and row interconnects and ALM
outputs in the same LAB.
Neighboring LABs, MLABs, M10K blocks, or digital signal processing (DSP) blocks from the left or right
can also drive the LAB’s local interconnect using the direct link connection.
The direct link connection feature minimizes the use of row and column interconnects, providing higher
performance and flexibility.
Altera Corporation
Logic Array Blocks and Adaptive Logic Modules in Cyclone V Devices
1-3
Local and Direct Link Interconnects
CV-52001