tx_analogreset
tx_digitalreset
rx_analogreset
rx_digital-
reset
pll_
powerdown
Transceiver Block
—
—
—
Yes
—
Receiver Phase Compensa-
tion FIFO
Receiver PMA
—
—
Yes
—
—
Receiver Buffer
—
—
Yes
—
—
Receiver CDR
—
—
Yes
—
—
Receiver Deserializer
Transmitter Standard PCS
—
Yes
—
—
—
Transmitter Phase
Compensation FIFO
—
Yes
—
—
—
Byte Serializer
—
Yes
—
—
—
8B/10B Encoder
—
Yes
—
—
—
Transmitter Bit-Slip
Transmitter PMA
Yes
—
—
—
—
Transmitter CGB
Yes
—
—
—
—
Serializer
Yes
—
—
—
—
Transmitter Buffer
Transceiver Power-Down
To maximize power savings, enable PMA hard power-down across all channels on a side of the device where
you do not use the transceivers.
The hard power-down granularity control of the transceiver PMA is per side. To enable PMA hard power-
down on the left or right side of the device, ground the transceiver power supply of the respective side.
Related Information
For information about the transceiver power supply operating conditions of the left and right side of Cyclone
V devices.
Document Revision History
Changes
Version
Date
• Changed term of User-Controlled
Reset Controller to User-Coded
Reset Controller.
Altera Corporation
Transceiver Reset Control in Cyclone V Devices
3-15
Transceiver Power-Down
CV-53003