2
Transceiver Clocking in Cyclone V Devices
2013.05.06
CV-53002
Send Feedback
This chapter provides information about the Cyclone
®
V transceiver clocking architecture. The chapter
describes the clocks that are required for operation, internal clocking architecture, and clocking options
when the transceiver interfaces with the FPGA fabric.
Figure 2-1: Transceiver Clocking Architecture Overview
Transceivers
FPGA
Fabric
FPGA Fabric-Transceiver
Interface Clocks
Transmit PLL
or CDR
Input Reference Clock
Transceiver
Channels
Internal Clocks
Related Information
Cyclone V Device Handbook: Known Issues
Lists the planned updates to the
Cyclone V Device Handbook
chapters.
Input Reference Clocking
This section describes how the reference clock for the transmitter PLL and CDR is provided to generate the
clocks required for transceiver operation.
Table 2-1: Input Reference Clock Sources
Jitter Performance
(6)
CDR
Transmitter PLL
Sources
CMU PLL
1
Yes
Yes
Dedicated
refclk
pin
2
Yes
Yes
REFCLK network
3
Yes
Yes
Dual-purpose RX / refclk pin
4
Yes
Yes
Fractional PLL
(6)
The lower number indicates better jitter performance.
©
2013 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, HARDCOPY, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words
and logos are trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other
words and logos identified as trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html
. Altera warrants performance of its semiconductor products to current specifications in accordance with
Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes
no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly
agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device specifications before relying on any published
information and before placing orders for products or services.
www.altera.com
101 Innovation Drive, San Jose, CA 95134