[SENSe:]CORRection:TRANsducer:VIEW
<State>
This command includes or excludes a figure of a transducer factor in the diagram.
Before you can use the command, you have to select a transducer factor with
[SENSe:]CORRection:TRANsducer:SELect
.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CORR:TRAN:SEL 'FACTOR'
CORR:TRAN:VIEW ON
Selects and displays a transducer factor.
[SENSe:]CORRection:TSET:BREak
<State>
This command turns a transducer break on and off.
Before you can use the command, you have to select a transducer set with
.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
See
Manual operation:
See
[SENSe:]CORRection:TSET:CATalog?
This command queries all transducer sets stored on the R&S
ESRP.
Return values:
<UsedDiskSpace>
Size of all available files containing transducer factors in byte.
<FreeDiskSpace>
Remaining disk space in bytes.
<FileInfo>
String containing the file information.
'<NameFileN>,<SizeFileN>'
<NameFileN>
Name of the file.
<SizeFileN>
Size of the file in bytes.
Example:
CORR:TSET:CAT?
would return, e.g.
3298,34482896896,'SET1,1520','SET2,1756'
Usage:
Query only