Spectrum Measurements
R&S
®
ESRP
277
User Manual 1175.7445.02 ─ 08
When measuring Spurious Emissions, using this softkey automatically opens the
"Sweep List" dialog (see
The submenu contains the following softkeys:
●
Normal (3 dB)
●
CISPR (6 dB)
●
MIL Std (6 dB)
Note that the 6
dB bandwidths are available only with option R&S
FSV-K54.
●
Channel
●
RRC
●
5-Pole (not available for sweep type "FFT")
For detailed information on filters see
Chapter 6.2.6.3, "Selecting the Appropriate Filter
Chapter 6.2.6.4, "List of Available RRC and Channel Filters"
Remote command:
[SENSe:]BANDwidth|BWIDth[:RESolution]:TYPE
Res BW CISPR / CISPR (6 dB)
Selects the measurement bandwidth for commercial EMC standards according to
CISPR.
If you select the bandwidth with the "Res BW CISPR" softkey, the R&S
ESRP automat-
ically changes the filter type to a 6
dB bandwidth.
Remote command:
Filter type:
[SENSe:]BANDwidth|BWIDth[:RESolution]:TYPE
Filter bandwidth:
[SENSe:]BANDwidth|BWIDth[:RESolution]
Res BW Mil Std/ MIL Std (6 dB)
Selects the measurement bandwidths for military EMC standards.
If you select the bandwidth with the "Res BW Mil Std" softkey, the R&S
ESRP automat-
ically changes the filter type to a 6
dB bandwidth.
Remote command:
Filter type:
[SENSe:]BANDwidth|BWIDth[:RESolution]:TYPE
Filter bandwidth:
[SENSe:]BANDwidth|BWIDth[:RESolution]
Sweep Points
Opens an edit dialog box to enter the number of measured values collected during a
single measurement.
For more information see
"Setting the Number of Sweep Points"
Remote command:
Freq (Lin Log)
Turns logarithmic scaling of the frequency axis on and off.
Measurements