Remote Control
R&S
®
ESRP
788
User Manual 1175.7445.02 ─ 08
<AVGPower>
ON | OFF
Turns average power evaluation on and off.
*RST:
OFF
<TriggerSource>
IMMediate | EXTernal | VIDeo | IFPower | RFPower
Selects a trigger source.
For more information see
*RST:
IMM
<TriggerSlope>
NEGative | POSitive
Selects the trigger slope.
*RST:
POS
<TriggerOffset>
Defines the trigger delay. The trigger delay is the time between
the detection of the trigger signal and the start of the measure-
ment at the next frequency point.
Range:
span = 0 Hz: (-sweep time) to 30 s; span > 10 Hz:
31.25 ns to 30 s
*RST:
0 s
<GateLength>
Defines the gate length for gated measurements.
Setting 0 seconds turns gated measurements off. Other values
activate the gated trigger function.
To perform gated measurements, the trigger source must be dif-
ferent from
IMMediate
.
Range:
31.25 ns to 30 s
*RST:
0 s
Example:
SENSe:LIST:POWer:SET ON,OFF,OFF,EXT,POS,10US,
434US
[SENSe:]LIST:POWer:STATe
<State>
This command turns the List Evaluation off.
Parameters:
<State>
OFF
Example:
SENS:LIST:POW:STAT OFF
11.5.1.15
Probe Configuration
............................................................................................... 789
Remote Commands in Spectrum Analyzer Mode