Remote Control
R&S
®
ESRP
761
User Manual 1175.7445.02 ─ 08
CALCulate<n>:STATistics:NSAMples
<NoMeasPoints>
This command sets the number of measurement points to be acquired for the statisti-
cal measurement functions.
Suffix:
<n>
.
irrelevant
Parameters:
<NoMeasPoints>
100 to 1E9
*RST:
100000
Example:
CALC:STAT:NSAM 500
Sets the number of measurement points to be acquired to 500.
Manual operation:
See
Retrieving Results
The following commands are required to retrieve the measurement results.
Commands useful to retrieve results described elsewhere:
●
●
CALCulate<n>:STATistics:CCDF:X<Trace>
...................................................................... 761
CALCulate<n>:STATistics:RESult<Trace>
........................................................................ 762
CALCulate<n>:STATistics:CCDF:X<Trace>
<Probability>
This command queries the results of the complementary cumulative distribution func-
tion (CCDF) for the specified probability (corresponding to the "Percent Marker" in the
display, see
on page 293).The suffix of X defines the trace number.
Suffix:
<n>
.
irrelevant
<Trace>
1...6
trace
Parameters:
<Probability>
P0_01: Level value for 0.01 % probability
P0_1: Level value for 0.1 % probability
P1: Level value for 1 % probability
P10: Level value for 10 % probability
Example:
CALC:STAT:CCDF:X1? P10
Returns the level values that are over 10 % above the mean
value.
Manual operation:
See