Service
Opens a submenu that contains additional functions for maintenance and/or trouble-
shooting.
NOTICE!
Risk of incorrect operation due to service functions. The service functions are
not necessary for normal measurement operation. However, incorrect use can affect
correct operation and/or data integrity of the R&S
ESRP.
Therefore, many of the functions can only be used after entering a password. They are
described in the instrument service manual.
Only user accounts with administrator rights are able to use service functions.
Input Source ← Service
Opens a submenu to select the input source for measurement.
The submenu contains the following options:
●
●
RF ← Input Source ← Service
Switches the input of the R&S
ESRP to the RF input connector (normal position). This
is the default setting.
Remote command:
DIAGnostic<n>:SERVice:INPut[:SELect]
Calibration Frequency RF ← Input Source ← Service
Opens an edit dialog box to set the generator frequency for the internal calibration.
Remote command:
DIAGnostic<n>:SERVice:INPut:PULSed:CFRequency
Reset Password ← Service
Deactivates all set passwords.
Remote command:
Selftest ← Service
Initiates the self-test of the instrument modules to identify a defective module if there
was a failure. All modules are checked consecutively and the test result is displayed.
Remote command:
Selftest Results ← Service
Opens the "Selftest Result" dialog box that contains the test results. In case of failure a
short description of the failed test, the defective module, the associated value range
and the corresponding test results are indicated.
Remote command:
DIAGnostic<n>:SERVice:STESt:RESult?