Remote Control
R&S
®
ESRP
640
User Manual 1175.7445.02 ─ 08
[SENSe:]BANDwidth|BWIDth[:RESolution]:AUTO
<State>
This command couples or decouples the resolution bandwidth to the selected fre-
quency.
The resolution bandwidth is coupled to the frequency only if you have selected the
Quasipeak, CISPR Average or CISPR RMS detector.
For more information see
Chapter 5.2.1, "Measurement Bandwidth"
Parameters:
<State>
ON | OFF
*RST:
ON
Example:
BAND:AUTO OFF
Decouples the measurement bandwidth from the frequency
range.
Manual operation:
See
[SENSe:]BANDwidth|BWIDth[:RESolution]:TYPE
<FilterType>
This command selects the type of resolution filter.
For detailed information on filters see
Chapter 6.2.6.3, "Selecting the Appropriate Filter
Chapter 6.2.6.4, "List of Available RRC and Channel Filters"
When changing the filter type, the next larger filter bandwidth is selected if the same
filter bandwidth is not available for the new filter type.
5 Pole filters are not available when using the sweep type "FFT".
Parameters:
<FilterType>
NORMal
Gaussian filters
CFILter
Channel filters
RRC
RRC filters
P5
5 Pole filters
CISPr (PULSe)
6 dB CISPR filter (commercial EMI standards)
Note: when the filter type is queried, the CISPR filter returns
'PULS'.
*RST:
NORMal
Example:
BAND:TYPE NORM
Remote Commands in Receiver Mode