Remote Control
R&S
®
ESRP
673
User Manual 1175.7445.02 ─ 08
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:DLIN2:STAT OFF
Manual operation:
See
"Display Line 1 / Display Line 2"
11.4.8.2
Using Frequency Lines
................................................................................................673
......................................................................................673
............................................................................................... 673
CALCulate<n>:FLINe<k>
<Frequency>
This command defines the position of a frequency line.
Suffix:
<n>
.
Selects the measurement window.
<k>
1 | 2
Selects the frequency line.
Parameters:
<Frequency>
Range:
0 Hz to fmax
*RST:
(STATe to OFF)
Example:
CALC:FLIN2 120MHz
Manual operation:
See
"Frequency Line 1 / Frequency Line 2 "
CALCulate<n>:FLINe<k>:STATe
<State>
This command turns a frequency line on and off.
Suffix:
<n>
.
Selects the measurement window.
<k>
1 | 2
Selects the frequency line.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:FLIN2:STAT ON
Manual operation:
See
"Frequency Line 1 / Frequency Line 2 "
CALCulate:TFLine:STATe
<State>
This command turns a frequency line coupled to the receiver frequency on and off.
Remote Commands in Receiver Mode