The Receiver Pipe x Status Register RPxSTATR indicates the coded buffer size which
represents the Remote Window Size of 2 Bytes to 64KBytes and the address prediction
factor that has been calculated for pipe x in the receiving controller.
0
[23:21],
[31:25]
r
Reserved
Read as 0; should be written with 0.
RPxSTATR (x = 0-3)
Receiver Pipe x Status Register
(7C
H
+4
H
*x)
Reset Value: 0000 0000
H
31
16 15
6 5 4 3
0
0
AP
0
BS
r
rh
r
rh
Field
Bits
Type Description
BS
[3:0]
rh
Buffer Size
This bit field indicates the size of pipe x Remote Window
in the receiving controller. It is updated by hardware
when a Copy Base Address Frame has been received
(see
0000
B
1-bit offset address of Remote Window
0001
B
2-bit offset address of Remote Window
0010
B
3-bit offset address of Remote Window
…
B
…
1110
B
15-bit offset address of Remote Window
1111
B
16-bit offset address of Remote Window
AP
[15:6]
rh
Address Prediction Factor
AP contains the address prediction factor that has been
calculated for pipe x in the receiving controller. It is a
signed 9-bit number with the sign in its most significant
bit (see
0
[5:4],
[31:16]
r
Reserved
Read as 0.
Field
Bits
Type Description