![Infineon Technologies TC1796 Скачать руководство пользователя страница 1469](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371469.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual
22-174
V2.0, 2007-07
MultiCAN, V2.0
0
7
r
Reserved
Read as 0; should be written with 0.
Table 22-15 Modification by Hardware of Bit Field RTO
Modification
Condition
Set to
TTCFGR.IRO
During reset (TTCFGR.IRO = 0) and Configuration Mode (write of
TTCFGR.IRO by software)
Set to
TTCFGR.IRO
Each time a potential time master receives a reference message with
a higher priority than its own
Decrement by 1 Each time a potential time master receives a reference message with
a lower priority than its own until -127 is reached
Set to 127
When the S2 state is entered
Set to 0
When the TTCAN node has correctly transmitted its reference
message (it is the current time master)
or
when a potential master receives a reference message with a priority
lower than its own and its RTO is positive
Field
Bits
Type Description