![Infineon Technologies TC1796 Скачать руководство пользователя страница 2015](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554372015.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Analog-to-Digital Converter (ADC)
User’s Manual
25-84
V2.0, 2007-07
ADC, V2.0
SYSTAT
Synchronization Status Register
(190
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
SY
REQ
0
rh
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CSR
EN
0
GRP
S
EMUX
RES
0
CHNRSY
rh
r
rh
rh
rh
r
rh
Field
Bits
Type Description
CHNRSY
[3:0]
rh
Channel to be Converted in Synchronized
Conversion
This bit field indicates the channel number of the
analog channel which is converted in synchronized
mode.
RES
[7:6]
rh
Conversion Resolution Status
This bit field indicates the resolution of the A/D
Converter for the conversion of the analog channel
determined by CHNRSY.
00
B
10-bit resolution
1
B
012-bit resolution
10
B
8-bit resolution
11
B
Reserved
EMUX
[9:8]
rh
External Multiplexer Status
This bit indicates the settings of the external
multiplexer control lines that is used during an A/D
conversion for the analog channel determined by
CHNRSY.
GRPS
10
rh
Status of Analog Input Multiplexer Group Select
This bit indicates the status of the analog input
multiplexer group select of the analog channel
determined by CHNRSY.
0
B
Analog input multiplexer group 0 selected
1
B