TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual
23-117
V2.0, 2007-07
MLI, V2.0
23.4.9
Receiver Interrupt Registers
The Receiver Interrupt Enable Register RIER contains the interrupt enable bits and the
clear bits for all receiver events. The bits marked w are always read as 0.
RIER
Receiver Interrupt Enable Register
(A4
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
DRA
IR
MPE
IR
PE
IR
ICE
R
CFR
IR3
CFR
IR2
CFR
IR1
CFR
IR0
ME
IR
NFR
IR
r
w
w
w
w
w
w
w
w
w
w
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
DRA
IE
M
PEIE
PEIE ICE
CFR
IE3
CFR
IE2
CFR
IE1
CFR
IE0
NFR
IE
r
rw
rw
rw
rw
rw
rw
rw
rw
rw
Field
Bits
Type Description
NFRIE
[1:0]
rw
Normal Frame Received Interrupt Enable
This bit field defines if an SRx output is activated if a
Normal Frame is correctly received.
00
B
The SRx activation is disabled.
01
B
The selected SRx line is activated each time a
Normal Frame is correctly received.
10
B
The selected SRx line is activated each time a
Normal Frame is correctly received that is not
handled automatically by the MLI move engine
(e.g. an Answer Frame).
11
B
Reserved
CFRIEx
(x = 0-3)
2 + x
rw
Command Received in Pipe x Interrupt Enable
This bit determines if an SRx output is activated if a
Command Frame for pipe x has been received correctly.
0
B
Command received in pipe x event is disabled for
activation of an SRx line.
1
B
Command received in pipe x event is enabled for
activation of an SRx line.