![Infineon Technologies TC1796 Скачать руководство пользователя страница 1840](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371840.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-185
V2.0, 2007-07
GPTA, V2.0
OIA
14
rw
Output Immediate Action
0
B
No immediate action required.
1
B
Action defined by bit field OCM must be
performed immediately.
OIA is always read as 0.
OUT
15
rh
Output State
0
B
LTCkOUT output line is 0.
1
B
LTCkOUT output line is 1.
0
[31:16] r
Reserved
Read as 0; should be written with 0.
LTCCTRk (k = 00-62)
Local Timer Cell Control Register k [Compare Mode]
(200
H
+k*8
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
OUT OIA
OCM
CEN SLL ILM EOA BYP SOH SOL REN OSM
MOD
rh
rw
rw
rh
rh
rw
rwh
rw
rw
rw
rw
rw
rw
Field
Bits
Type Description
MOD
[1:0]
rw
Mode Control Bits
00
B
LTCk operates in Capture Mode.
01
B
LTCk operates in Compare Mode.
10
B
LTCk operates in Free-Running Timer Mode.
11
B
LTCk operates in Reset Timer Mode.
OSM
2
rw
One Shot Mode Enable
0
B
LTCk is continuously enabled.
1
B
LTCk is enabled for one event only.
Field
Bits
Type Description